DETERMINATION OF GLUTATHIONE IN BIOLOGICAL SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

被引:14
作者
GOTTI, R
ANDRISANO, V
GATTI, R
CAVRINI, V
CANDELETTI, S
机构
[1] DEPT PHARMACEUT SCI,I-40126 BOLOGNA,ITALY
[2] DEPT PHARMACOL,I-40126 BOLOGNA,ITALY
关键词
D O I
10.1002/bmc.1130080612
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A selective and sensitive high performance liquid chromatographic (HPLC) method has been developed for the determination of reduced glutathione (GSH) in biological samples (rat liver, spleen and plasma). The method involved a prechromatographic thiol derivatization with methyl 4-(6-methoxynaphthalen-2-yl)-4-oxo-2-butenoate; the reaction was rapid (5 min) under mild conditions (pH 7.5 and ambient temperature) and selective for the sulphydryl group. The thiol adducts were separated on a reversed-phase C-18 column using acetonitrile: 0.05 M triethylammonium (TEA) phosphate (pH 4) solution 32:68 (v/v) as the mobile phase. Fluorescence detection (lambda(em)=450 nm; lambda(exc)=310 nm) was used and the detection limit (S/N=3) was about 0.5 pmole of the injected GSH adduct. The method was also applied to the determination of total glutathione in rat plasma after a preliminary reduction with dithiothreitol.
引用
收藏
页码:306 / 308
页数:3
相关论文
共 22 条
[1]  
ANDERSON ME, 1980, J BIOL CHEM, V255, P9530
[2]  
BAEYENS WRG, 1988, ASTM SPEC TECH PUBL, V1009, P83
[3]   GLUTATHIONE AND CYSTEINE MEASUREMENT IN BIOLOGICAL SAMPLES BY HPLC WITH A GLASSY-CARBON WORKING DETECTOR [J].
CARVALHO, FD ;
REMIAO, F ;
VALE, P ;
TIMBRELL, JA ;
BASTOS, ML ;
FERREIRA, MA .
BIOMEDICAL CHROMATOGRAPHY, 1994, 8 (03) :134-136
[4]  
CAVRINI V, 1982, FARMACO-ED SCI, V37, P171
[5]   MEASUREMENT OF TISSUE SULFHYDRYLS AND DISULFIDES IN TISSUE PROTEIN AND NONPROTEIN FRACTIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ELECTROCHEMICAL DETECTION [J].
DUPUY, D ;
SZABO, S .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (01) :107-119
[6]  
FAHEY RC, 1989, GLUTATHIONE CHEM B A, P304
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ALIPHATIC THIOLS WITH AROYLACRYLIC ACIDS AS FLUOROGENIC PRECOLUMN DERIVATIZATION REAGENTS [J].
GATTI, R ;
CAVRINI, V ;
ROVERI, P ;
PINZAUTI, S .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :451-458
[8]   DETERMINATION OF GLUTATHIONE IN PHARMACEUTICALS AND COSMETICS BY HPLC WITH UV AND FLUORESCENCE DETECTION [J].
GOTTI, R ;
ANDRISANO, V ;
CAVRINI, V ;
BONGINI, A .
CHROMATOGRAPHIA, 1994, 39 (1-2) :23-28
[9]   THE SIMULTANEOUS DETERMINATION OF OXIDIZED AND REDUCED GLUTATHIONES IN LIVER-TISSUE BY ION-PAIRING REVERSE PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A COULOMETRIC ELECTROCHEMICAL DETECTOR [J].
HARVEY, PRC ;
ILSON, RG ;
STRASBERG, SM .
CLINICA CHIMICA ACTA, 1989, 180 (03) :203-212
[10]  
KOSOWER EM, 1989, GLUTATHIONE CHEM B A, P104