Simultaneous automatic determination of catecholamines and their 3-O-methyl metabolites in rat plasma by high-performance liquid chromatography using peroxyoxalate chemiluminescence reaction

被引:78
作者
Tsunoda, M [1 ]
Takezawa, K [1 ]
Santa, T [1 ]
Imai, K [1 ]
机构
[1] Univ Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
关键词
catecholamines; chemiluminescence; normetanephrine; metanephrine; rat plasma;
D O I
10.1006/abio.1999.4043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly specific and sensitive automated high-performance liquid chromatographic method for the simultaneous determination of catecholamines (CAs; norepinephrine, epinephrine, and dopamine) and their 3-O-methyl metabolites (normetanephrine, metanephrine, and 3-methoxytyramine) is described. Automated precolumn ion-exchange extraction of diluted plasma is coupled with HPLC separation of CAs and their 3-O-methyl metabolites on an ODS column, postcolumn coulometric oxidation, fluorescence derivatization with ethylenediamine, and finally peroxyoxalate chemiluminescence reaction detection. The detection limits were about 3 fmol for norepinephrine, epinephrine, and dopamine, 5 fmol for normetanephrine, and 10 fmol for metanephrine and 3-methoxytyramine (signal-to-noise ratio of 3). Fifty microliters of rat plasma was used and 4-methoxytyramine was employed as an internal standard. The relative standard deviations for the method (n = 5) were 2.5-7.6% for the intraday assay and 6.3-9.1% for the interday assay. The method was applicable to the determination of normetanephrine and metanephrine in 50 Ed. of rat plasma. 1999 Academic Press.
引用
收藏
页码:386 / 392
页数:7
相关论文
共 24 条
[21]   SIMULTANEOUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CATECHOLAMINE-RELATED COMPOUNDS BY POST-COLUMN DERIVATIZATION INVOLVING COULOMETRIC OXIDATION FOLLOWED BY FLUORESCENCE REACTION [J].
NOHTA, H ;
YAMAGUCHI, E ;
OHKURA, Y ;
WATANABE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 467 (01) :237-247
[22]   DETERMINATION OF FREE AND CONJUGATED NORMETANEPHRINE AND METANEPHRINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
PAGLIARI, R ;
COTTETEMARD, JM ;
PEYRIN, L .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 563 (01) :23-36
[23]  
PARKER NC, 1986, CLIN CHEM, V32, P1473
[24]   DETERMINATION OF URINARY NORMETANEPHRINE, METANEPHRINE AND 3-METHOXYTYRAMINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - COMPARISON BETWEEN AUTOMATED COLUMN-SWITCHING AND MANUAL DUAL-COLUMN SAMPLE PURIFICATION METHODS [J].
VOLIN, P .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 578 (02) :165-174