Scanning electron microscopic assessment of coating irregularities and their precursors in unexpanded durable polymer-based drug-eluting stents

被引:22
作者
Basalus, Mounir W. Z. [1 ]
Tandjung, Kenneth [1 ]
van Westen, Thea [2 ]
Sen, Hanim [1 ]
van der Jagt, Pasquelle K. N. [2 ]
Grijpma, Dirk W. [2 ]
van Apeldoorn, Aart A. [2 ]
von Birgelen, Clemens [1 ,2 ]
机构
[1] Thoraxctr Twente, Dept Cardiol, NL-7513 ER Enschede, Netherlands
[2] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
关键词
drug-eluting stent; DES; coating irregularity; durable polymer; scanning electron microscopy; percutaneous coronary intervention; coronary artery disease; BARE-METAL STENTS; METAANALYSIS; TRIALS;
D O I
10.1002/ccd.23273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To assess and quantify coating irregularities on unexpanded and expanded durable polymer-based drug-eluting stents (DES) to gain insights into the origin of coating irregularities. Background: Previous scanning electron microscopy (SEM) studies in various expanded DES revealed differences in frequency and size of coating irregularities between DES types and specific distribution patterns, however, the origin of these irregularities is unclear. Methods: We assessed at bench side a total of 1,200 SEM images obtained in 30 DES samples (15 expanded and 15 unexpanded) of Cypher Select Plus, Taxus Liberte, Endeavor, Xience V, and resolute. Results: For most coating irregularities seen on expanded DES (72%; 23/32), a matching irregularity (n = 18/23) and/or its precursor (n = 11/23) was observed in unexpanded DES. Unexpanded Cypher select showed (small) crater lesions and cracks together with precursors of peeling. On unexpanded Taxus Liberte, thinning of polymer, small bare metal areas, wrinkles, and one precursor type were found. Unexpanded endeavor showed cracks, small bare metal areas, crater lesions, and precursors of the latter. Unexpanded Xience V and resolute mainly revealed crater lesions and their precursors. On unexpanded versus expanded DES, there was no difference in measured frequency of coating irregularities and precursors (P = ns) with the exception of more bare metal areas on expanded Taxus Liberte (P = 0.01). Conclusions: Most coating irregularities, or the potential to develop them, are inherent to the unexpanded DES. Important determinants of the formation of coating irregularities may be the stent geometry and the physical properties of the coating, while stent-balloon interaction plays no major role. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:644 / 653
页数:10
相关论文
共 14 条
[1]   Scanning electron microscopic assessment of the biodegradable coating on expanded biolimus-eluting stents [J].
Basalus, Mounir W. Z. ;
van Houwelingen, K. Gert ;
Ankone, Marc ;
de Man, Frits H. A. F. ;
von Birgelen, Clemens .
EUROINTERVENTION, 2009, 5 (04) :505-510
[2]   Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopy [J].
Basalus, Mounir W. Z. ;
Ankone, Marc J. K. ;
van Houwelingen, K. Gert ;
de Man, Frits H. A. F. ;
von Birgelen, Clemens .
EUROINTERVENTION, 2009, 5 (01) :157-165
[3]  
Basalus MW, 2010, INTERV CARDIOL, V2, P159
[4]   Restenosis Delineating the Numerous Causes of Drug-Eluting Stent Restenosis [J].
Farooq, Vasim ;
Gogas, Bill D. ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (02) :195-205
[5]   Coronary Stents Looking Forward [J].
Garg, Scot ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (10) :S43-S78
[6]   Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions [J].
Grube, E ;
Silber, S ;
Hauptmann, KE ;
Mueller, R ;
Buellesfeld, L ;
Gerckens, U ;
Russell, ME .
CIRCULATION, 2003, 107 (01) :38-42
[7]   Safety and Efficacy of Drug-Eluting and Bare Metal Stents Comprehensive Meta-Analysis of Randomized Trials and Observational Studies [J].
Kirtane, Ajay J. ;
Gupta, Anuj ;
Iyengar, Srinivas ;
Moses, Jeffrey W. ;
Leon, Martin B. ;
Applegate, Robert ;
Brodie, Bruce ;
Hannan, Edward ;
Harjai, Kishore ;
Jensen, Lisette Okkels ;
Park, Seung-Jung ;
Perry, Raphael ;
Racz, Michael ;
Saia, Francesco ;
Tu, Jack V. ;
Waksman, Ron ;
Lansky, Alexandra J. ;
Mehran, Roxana ;
Stone, Gregg W. .
CIRCULATION, 2009, 119 (25) :3198-U78
[8]   Stent thrombosis in randomized clinical trials of drug-eluting stents [J].
Mauri, Laura ;
Hsieh, Wen-hua ;
Massaro, Joseph M. ;
Ho, Kalon K. L. ;
D'Agostino, Ralph ;
Cutlip, Donald E. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :1020-1029
[9]   A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. [J].
Morice, M ;
Serruys, PW ;
Sousa, JE ;
Fajadet, J ;
Hayashi, EB ;
Perin, M ;
Colombo, A ;
Schuler, G ;
Barragan, P ;
Guagliumi, G ;
Molnar, F ;
Falotico, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) :1773-1780
[10]   Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysis [J].
Nordmann, Alain Joel ;
Briel, Matthias ;
Bucher, Heiner Claudins .
EUROPEAN HEART JOURNAL, 2006, 27 (23) :2784-2814