An approach to conductometric immunosensor based on phthalocyanine thin film

被引:21
作者
Sergeyeva, TA
Lavrik, NV
Rachkov, AE
Kazantseva, ZI
El'skaya, AV
机构
[1] Natl Acad Sci Ukraine, Inst Mol Biol & Genet, UA-252143 Kiev, Ukraine
[2] Natl Acad Sci Ukraine, Inst Semicond Phys, UA-252650 Kiev, Ukraine
关键词
electrochemical immunoassay; conductometric method; IgG; immunosensor; horseradish peroxidase; enzyme sensor; tetra-tert-butyl Cu phthalocyanine; Langmuir-Blodgett films;
D O I
10.1016/S0956-5663(97)00117-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new approach to conductometric biosensors utilizing iodine-sensitive phthalocyanine thin films has been proposed. The excellent sensitivity of the tetra-tert-butyl copper phthalocyanine (ttb-CuPc) to free iodine was used for the first time to detect a peroxidase-initiated reaction in an aqueous medium. To minimize the interfering effect of aqueous electrolytes on the impedance responses of the ttb-CuPc film itself, Au/Cr interdigitated planar electrodes bearing ttb-CuPc thin films were protected with hydrophobic gas-permeable membranes, namely thermally evaporated calixarene or plasma polymerized hexamethyldisiloxane films. Impedance spectroscopy data were analyzed in order to define the optimal operating frequency. An enzyme sensor with peroxidase immobilized in a cross-linked albumin matrix was tested. Its impedance responses were studied under variation of the substrate concentration, pH, ionic strength and buffer capacity. These results were used to define conditions for peroxidase-linked immunoassay in subsequent tests. With the developed sensor, concentrations of IgG in 0.2-2 mu g/ml range were measured in a competitive mode with satisfactory accuracy. The detection of Ige in both test solutions and blood serum samples has been demonstrated. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:359 / 369
页数:11
相关论文
共 16 条
  • [1] DIRECT DETECTION OF IMMUNOSPECIES BY CAPACITANCE MEASUREMENTS
    BATAILLARD, P
    GARDIES, F
    JAFFREZICRENAULT, N
    MARTELET, C
    COLIN, B
    MANDRAND, B
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (21) : 2374 - 2379
  • [2] BOITIEUX JL, 1979, CLIN CHEM, V25, P318
  • [3] DESILVA MS, 1995, BIOSENS BIOELECTRON, V10, P669
  • [4] PROTOTYPE, SOLID-PHASE, GLUCOSE BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    PATTON, DT
    [J]. ANALYST, 1995, 120 (07) : 1973 - 1981
  • [5] GUILBAULT GG, 1973, ANAL LETT, V6, P301, DOI 10.1080/00032717308062891
  • [6] HALL EAH, 1990, BIOSENSORS, P1
  • [7] KAMPFRATH G, 1989, ANAL LETT, V22, P2423
  • [8] Karyakin AA, 1996, RUSS J ELECTROCHEM+, V32, P939
  • [9] LENADO RL, 1973, ANAL CHEM, V45, P826
  • [10] LESNOFF CC, 1989, PHTHALOCYANINES PROP, P1