Monolithic valves for microfluidic chips based on thermoresponsive polymer gels

被引:97
作者
Luo, QZ
Mutlu, S
Gianchandani, YB
Svec, F
Fréchet, JMJ [1 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Lab, Div Mat Sci, Berkeley, CA 94720 USA
关键词
lower critical solution temperature; microfluidic device; miniaturization; monolith; thermoresponsive polymer; valve;
D O I
10.1002/elps.200305577
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The direct preparation of thermoresponsive monolithic copolymers by photopatterning of a liquid phase consisting of an aqueous solution of N-isopropylacrylamide, N-ethylacrylamide, N,N'-methylenebisacrylamide, and 4,4'-azobis(4-cyanovaleric acid) has been studied and the products used as valves within the channels of microfluidic devices. The volume change associated with the polymer phase transition at its lower critical solution temperature (LCST) leads to the rapid swelling and the deswelling of the 2.5% cross-linked monolithic gel thus enabling the polymer to close or open the channel and to function as a nonmechanically actuated valve. The LCST at which the valve switches was easily adjusted within a range of 35degreesC-74degreesC by varying the proportions of the monovinyl monomers in the polymerization mixture. The closed valve holds pressures of up to 18 MPa without noticeable dislocation, structural damage, or leakage. In contrast, following deswelling by raising the temperature above LCST the valve offers no appreciable flow resistance since its large, micrometer-size pores are open. Laser-triggered photobleaching of a fluorescent dye contained in the liquid phase enabled monitoring of flow through the device and determination of the times required to open and close the valve. The valves are characterized by very fast actuation times in a range of 1-4 s depending on the type of device. No changes in performance were observed even after repeated open-close cycling of the valves.
引用
收藏
页码:3694 / 3702
页数:9
相关论文
共 56 条
  • [1] Toward a human blood serum proteome - Analysis by multidimensional separation coupled with mass spectrometry
    Adkins, JN
    Varnum, SM
    Auberry, KJ
    Moore, RJ
    Angell, NH
    Smith, RD
    Springer, DL
    Pounds, JG
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (12) : 947 - 955
  • [2] Arndt KF, 2000, POLYM ADVAN TECHNOL, V11, P496, DOI 10.1002/1099-1581(200008/12)11:8/12<496::AID-PAT996>3.3.CO
  • [3] 2-Z
  • [4] Micro total analysis systems. 2. Analytical standard operations and applications
    Auroux, PA
    Iossifidis, D
    Reyes, DR
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2637 - 2652
  • [5] Microfluidic tectonics: A comprehensive construction platform for microfluidic systems
    Beebe, DJ
    Moore, JS
    Yu, Q
    Liu, RH
    Kraft, ML
    Jo, BH
    Devadoss, C
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (25) : 13488 - 13493
  • [6] Functional hydrogel structures for autonomous flow control inside microfluidic channels
    Beebe, DJ
    Moore, JS
    Bauer, JM
    Yu, Q
    Liu, RH
    Devadoss, C
    Jo, BH
    [J]. NATURE, 2000, 404 (6778) : 588 - +
  • [7] A micromachined silicon valve driven by a miniature bi-stable electro-magnetic actuator
    Böhm, S
    Burger, GJ
    Korthorst, MT
    Roseboom, F
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 80 (01) : 77 - 83
  • [8] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [9] Poly(N-ethylacrylamide) hydrogels for lignin separation
    Cai, WS
    Gupta, RB
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (15) : 3406 - 3412
  • [10] Electrothermally activated paraffin microactuators
    Carlen, ET
    Mastrangelo, CH
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2002, 11 (03) : 165 - 174