Residual solvents determination in pharmaceutical products by GC-HS and GC-MS-SPME

被引:50
作者
Camarasu, CC [1 ]
Mezei-Szuts, M [1 ]
Varga, GB [1 ]
机构
[1] Gedeon Richter Ltd, Cent Analyt Lab, H-1103 Budapest, Hungary
关键词
extraction methods; solid phase microextraction; residual solvent analysis; headspace analysis;
D O I
10.1016/S0731-7085(98)00276-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction (SPME) has been applied to the residual solvents determination in pharmaceutical products and was compared with the static headspace. Three fibers with different polymer films were compared and the polydimethylsiloxane/divinylbenzene coated fiber was found to be the most sensitive for the analyzed analytes. Between the investigated sample preparation techniques, gastight-SPME proved to be the most sensitive, with DL values ranging from 5 pg ml(-1) to 2 ng ml(-1). Headspace SPME is more precise, with RSD of peak areas values ranging from 2 to 3%. The headspace SPME method was successfully validated. The validation data are reported in the text. The most important difference between the two techniques is that the gastight SPME showed better behavior towards very volatile solvents. Compared with the static headspace technique, both SPME methods showed superior results, being compatible with the pharmaceutical samples. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:623 / 638
页数:16
相关论文
共 13 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   Analysis of chloro- and nitroanilines and -benzenes in soils by headspace solid-phase microextraction [J].
Fromberg, A ;
Nilsson, T ;
Larsen, BR ;
Montanarella, L ;
Facchetti, S ;
Madsen, JO .
JOURNAL OF CHROMATOGRAPHY A, 1996, 746 (01) :71-81
[3]  
Gorecki T, 1995, J HIGH RES CHROMATOG, V18, P161, DOI DOI 10.1002/JHRC.1240180305
[4]   Solid-phase microextraction for the analysis of human breath [J].
Grote, C ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :587-596
[5]  
LKSO H, 1997, ANAL CHEM, V69, P1866
[6]   Calibration of solid phase microextraction for air analyses based on physical chemical properties of the coating [J].
Martos, PA ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :206-215
[7]   Sensitive, simultaneous determination of organomercury, -lead, and -tin compounds with headspace solid phase microextraction capillary gas chromatography combined with inductively coupled plasma mass spectrometry [J].
Moens, L ;
DeSmaele, T ;
Dams, R ;
VandenBroeck, P ;
Sandra, P .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1604-1611
[8]  
MORCILLO Y, 1995, J HIGH RES CHROMATOG, V18, P767
[9]   APPLICATION OF SOLID-PHASE MICROEXTRACTION TO THE HEADSPACE GAS-CHROMATOGRAPHIC ANALYSIS OF HALOGENATED VOLATILES IN SELECTED FOODS [J].
PAGE, BD ;
LACROIX, G .
JOURNAL OF CHROMATOGRAPHY, 1993, 648 (01) :199-211
[10]   Derivatization/solid-phase microextraction: New approach to polar analytes [J].
Pan, L ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :196-205