Electrothermal atomic absorption spectrometric determination of cadmium in Bangladeshi vegetables with a metal tube atomizer and slurry sampling technique

被引:6
作者
Amin, MN [1 ]
Kaneco, S
Suzuki, T
Ohta, K
机构
[1] Mie Univ, Fac Engn, Dept Chem Mat, Tsu, Mie 5148507, Japan
[2] Mie Univ, Environm Preservat Ctr, Tsu, Mie 5148507, Japan
关键词
electrothermal atomic absorption spectrometry; metal tube atomizer; slurry sampling technique; cadmium; Bangladeshi vegetables;
D O I
10.1080/03067310310001608777
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ultrasonic slurry sampling electrothermal atomic absorption spectrometry with a molybdenum tube atomizer has been applied for the determination of cadmium in vegetable samples in Bangladesh. The suspension-stabilizing medium was 10% glycerol solution. The optimum pyrolysis temperature was 300degreesC. The detection limit was 13 fg (3 S/N ). Matrix element interference was studied and it was found that thiourea as a chemical modifier eliminated the interference. The results for the determination of cadmium in vegetable samples by the proposed method were in good agreement with those measured in dissolved acid-digested samples. The method enables rapid calibration, and simple and rapid analysis of cadmium in vegetable samples at low cost.
引用
收藏
页码:1035 / 1044
页数:10
相关论文
共 30 条
[1]   Electrothermal atomic absorption spectrometric determination of lead in calcium drug samples by direct atomization technique [J].
Ahsan, S ;
Kaneco, S ;
Ohta, K ;
Mizuno, T ;
Suzuki, T ;
Miyada, M ;
Taniguchi, Y .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :279-284
[2]   Determination of trace lead impurities in pure copper slurry samples by electrothermal atomic absorption spectrometry with molybdenum tube atomizer [J].
Ahsan, S ;
Kaneco, S ;
Ohta, K ;
Mizuno, T .
ANALUSIS, 2000, 28 (05) :413-418
[3]   Arsenic and heavy metal contamination of vegetables grown in Samta village, Bangladesh [J].
Alam, MGM ;
Snow, ET ;
Tanaka, A .
SCIENCE OF THE TOTAL ENVIRONMENT, 2003, 308 (1-3) :83-96
[4]   Determination of manganese in herbal medicine samples by slurry-sampling electrothermal atomic absorption spectrometry with a metal tube atomizer [J].
Amin, MN ;
Kaneco, S ;
Suzuki, T ;
Taniguchi, Y ;
Ohta, K .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (03) :205-208
[5]   Slurry sampling electrothermal atomic absorption spectrometric determination of copper in herbal medicine samples with a molybdenum tube atomizer [J].
Amin, N ;
Kaneco, S ;
Suzuki, T ;
Ohta, K .
MICROCHEMICAL JOURNAL, 2003, 74 (02) :181-186
[6]  
[Anonymous], 1992, ENV HLTH CRIT
[7]   SOLID SAMPLING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING COMMERCIAL ATOMIZERS - A REVIEW [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (05) :353-374
[8]   EVALUATION OF THE LVOV PLATFORM AND MATRIX MODIFICATION FOR THE DETERMINATION OF ALUMINUM IN SERUM [J].
BETTINELLI, M ;
BARONI, U ;
FONTANA, F ;
POISETTI, P .
ANALYST, 1985, 110 (01) :19-22
[10]   NOVEL SAMPLING SYSTEM FOR DIRECT ANALYSIS OF POWDERS BY ATOMIC-ABSORPTION SPECTROMETRY [J].
FULLER, CW ;
THOMPSON, I .
ANALYST, 1977, 102 (1211) :141-143