Optimal pressure conditions for unbiased external ion accumulation in a two-dimensional radio-frequency quadrupole for Fourier transform ion cyclotron resonance mass spectrometry

被引:10
作者
Belov, ME [1 ]
Gorshkov, MV [1 ]
Alving, K [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1002/rcm.459
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When combined with on-line separations (e.g., capillary liquid chromatography (LC)), Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) provides a powerful tool for biological applications, and particularly proteomic studies. The sensitivity, dynamic range, and duty cycle provided by FTICR-MS have been shown to be increased by ion trapping and accumulation in a two-dimensional (2D) radio-frequency (rf)-only multipole positioned externally to an FTICR cell. However, it is important that ions be detected across the desired m/z range without a significant bias. In this work we found that pressure inside the accumulation rf-quadrupole plays an important role in obtaining 'unbiased' ion accumulation. Pressure optimization was performed in both pulsed and continuous modes. It was found that unbiased accumulation in a 2D rf-only quadrupole could be achieved in the pressure range of 5 X 10(-4) to 5 x 10 (-3) Torr. External ion accumulation performed at the optimal pressure resulted in an increase in both the spectrum acquisition rates and dynamic range. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1988 / 1996
页数:9
相关论文
共 28 条
  • [21] External accumulation of ions for enhanced electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Senko, MW
    Hendrickson, CL
    Emmett, MR
    Shi, SDH
    Marshall, AG
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (09) : 970 - 976
  • [22] Todd J.F.J., 1995, PRACTICAL ASPECTS IO, V1
  • [23] Tolmachev AV, 2000, RAPID COMMUN MASS SP, V14, P1907, DOI 10.1002/1097-0231(20001030)14:20<1907::AID-RCM111>3.0.CO
  • [24] 2-M
  • [25] Voyksner RD, 1999, RAPID COMMUN MASS SP, V13, P1427, DOI 10.1002/(SICI)1097-0231(19990730)13:14<1427::AID-RCM662>3.0.CO
  • [26] 2-5
  • [27] Mass-selective ion accumulation and fragmentation in a linear octopole ion trap external to a Fourier transform ion cyclotron resonance mass spectrometer
    Wang, Y
    Shi, SDH
    Hendrickson, CL
    Marshall, AG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 198 (1-2) : 113 - 120
  • [28] MACROSCOPIC PARTICLE MOTION IN QUADRUPOLE FIELDS
    WHETTEN, NR
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1974, 11 (02): : 515 - 518