Diffusion-weighted MR imaging: Navigated multi-shot SE EPI technique for clinical use.

被引:8
作者
Murtz, P
Flacke, S
Traber, F
Keller, E
Gieseke, J
Folkers, P
Schild, HH
机构
[1] Univ Bonn, Radiol Klin, D-53105 Bonn, Germany
[2] Philips Med Syst, Best, Netherlands
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1998年 / 168卷 / 06期
关键词
diffusion-weighted magnetic resonance imaging; diffusion coefficient; SE EPI sequence; navigator echo correction; tissue characterisation;
D O I
10.1055/s-2007-1015284
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of a navigated multi-shot SE EPI sequence for routine clinical use in MR diffusion imaging, Methods: We compared a multi-shot SE EPI sequence with the conventional SE sequence as well as with a single-shot SE EPI sequence on a standard 1.5 Tesla MR-scanner (ACS-NT, Philips Medical Systems) with a conventional gradient system (10 mT/m). Image quality and the reproducibility of the apparent diffusion coefficient were analysed with phantoms and with healthy volunteers. The diffusion coefficients of different brain areas were determined in a group of twenty volunteers. Results: The multi-shot SE EPI sequence showed considerably shorter measurement times and smaller motion artifacts than the SE sequence and was less sensitive to susceptibility artifacts than the single-shot version. The reproducibility of the diffusion coefficients was better than 10%. Conclusion: The navigated multi-shot SE technique is more practicable and meaningful than the SE and the single-shot SE EPI techniques on a standard 1.5 Tesla MR-scanner with a conventional gradient system. In our opinion it is now the best method for diffusion imaging and should be preferred in clinical use. The determination of diffusion coefficients yields reliable results and characteristic values for different tissue can be obtained.
引用
收藏
页码:580 / 588
页数:13
相关论文
共 25 条
[1]   ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[2]   Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes [J].
Butts, K ;
deCrespigny, A ;
Pauly, JM ;
Moseley, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :763-770
[3]  
CHEE MW, 1997, P 5 SCI M ISMRM, P1709
[4]   ANISOTROPIC DIFFUSION IN HUMAN WHITE MATTER - DEMONSTRATION WITH MR TECHNIQUES INVIVO [J].
CHENEVERT, TL ;
BRUNBERG, JA ;
PIPE, JG .
RADIOLOGY, 1990, 177 (02) :401-405
[5]  
CHIEN D, 1992, AM J NEURORADIOL, V13, P1097
[6]   Diffusion MRI: Precision, accuracy and flow effects [J].
Conturo, TE ;
McKinstry, RC ;
Aronovitz, JA ;
Neil, JJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :307-332
[7]   APPARENT DIFFUSION-COEFFICIENT MAPPING OF EXPERIMENTAL FOCAL CEREBRAL-ISCHEMIA USING DIFFUSION-WEIGHTED ECHO-PLANAR IMAGING [J].
DARDZINSKI, BJ ;
SOTAK, CH ;
FISHER, M ;
HASEGAWA, Y ;
LI, LM ;
MINEMATSU, K .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :318-325
[8]   NAVIGATED DIFFUSION IMAGING OF NORMAL AND ISCHEMIC HUMAN BRAIN [J].
DECRESPIGNY, AJ ;
MARKS, MP ;
ENZMANN, DR ;
MOSELEY, ME .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :720-728
[9]   ECHO-PLANAR MR-IMAGING [J].
EDELMAN, RR ;
WIELOPOLSKI, P ;
SCHMITT, F .
RADIOLOGY, 1994, 192 (03) :600-612
[10]   MR IMAGING OF ANISOTROPICALLY RESTRICTED DIFFUSION OF WATER IN THE NERVOUS-SYSTEM - TECHNICAL, ANATOMIC, AND PATHOLOGICAL CONSIDERATIONS [J].
HAJNAL, JV ;
DORAN, M ;
HALL, AS ;
COLLINS, AG ;
OATRIDGE, A ;
PENNOCK, JM ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (01) :1-18