Automated embolus identification using a rule-based expert system

被引:28
作者
Fan, L
Evans, DH
Naylor, AR
机构
[1] Univ Leicester, Leicester Warwick Med Sch, Dept Med Phys, Leicester, Leics, England
[2] Univ Leicester, Leicester Warwick Med Sch, Dept Surg, Leicester, Leics, England
关键词
carotid artery disease; cerebral embolism; Doppler ultrasound; emboli detection; expert systems; signal processing; transcranial Doppler sonography;
D O I
10.1016/S0301-5629(01)00414-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Transcranial Doppler ultrasound (US) can be used to detect microemboli in the cerebral circulation, but is still limited because it usually relies on "human experts" (HEs) to identify signals corresponding to embolic events. The purpose of this study was to develop an automatic system that could replace the HE and, thus, make the technique more widely applicable and, potentially, more reliable. An expert system, based around a digital signal-processing board, analysed Doppler signal patterns in both the time domain and frequency domain. The system was trained and tested on Doppler signals recorded during the dissection and recovery phases of carotid endarterectomy. It was tested with 74 separate 2.5-min recordings that contained at least 575 artefacts in addition to 253 s. of diathermy interference. The results were compared with the results obtained by three HEs. Using a "gold-standard" that classified any event detected by the majority of HEs as an embolus, the automatic system displayed a sensitivity of 94.7% and a specificity of 95.1% for 1151 candidate events 7 dB or more above the clutter (signal-to-clutter ratio, SCR, greater than or equal to 7 dB), and 89.6% and 95.3%, respectively, for 2098 candidate events with SCR greater than or equal to 5 dB. The system had a very similar performance to individual HEs for SCR greater than or equal to 7dB, and was only marginally worse for SCR : 5 dB. (E-mail: dhe@le.ac.uk) (C) 2001 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1065 / 1077
页数:13
相关论文
共 39 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]   THE SIGNIFICANCE OF MICROEMBOLI DETECTION BY MEANS OF TRANSCRANIAL DOPPLER ULTRASONOGRAPHY MONITORING IN CAROTID ENDARTERECTOMY [J].
ACKERSTAFF, RGA ;
JANSEN, C ;
MOLL, FL ;
VERMEULEN, FEE ;
HAMERLIJNCK, RPHM ;
MAUSER, HW .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) :963-969
[3]   Carotid endarterectomy and intraoperative emboli detection: Correlation of clinical, transcranial Doppler, and magnetic resonance findings [J].
Ackerstaff, RGA ;
Jansen, C ;
Moll, FL .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (05) :543-550
[4]   THEORETICAL-STUDY OF THE SCATTERING OF ULTRASOUND FROM BLOOD [J].
ANGELSEN, BAJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (02) :61-67
[5]  
Braekken SK, 1998, J NEUROL NEUROSUR PS, V65, P573
[6]   TIME FREQUENCY-DISTRIBUTIONS - A REVIEW [J].
COHEN, L .
PROCEEDINGS OF THE IEEE, 1989, 77 (07) :941-981
[7]   Evaluation of new online automated embolic signal detection algorithm, including comparison with panel of international experts [J].
Cullinane, M ;
Reid, G ;
Dittrich, R ;
Kaposzta, Z ;
Ackerstaff, R ;
Babikian, V ;
Droste, DW ;
Grossett, D ;
Siebler, M ;
Valton, L ;
Markus, HS .
STROKE, 2000, 31 (06) :1335-1341
[8]   Variability in occurrence of embolic signals in long term transcranial Doppler recordings [J].
Droste, DW ;
Decker, W ;
Siemens, HJ ;
Kaps, M ;
SchulteAltedorneburg, G .
NEUROLOGICAL RESEARCH, 1996, 18 (01) :25-30
[9]  
EVANS DH, 1997, ULTRASOUND MED BI S1, V23, pS140
[10]  
EVANS DH, 1999, TRANSCRANIAL DOPPLER, P141