Variability in occurrence of embolic signals in long term transcranial Doppler recordings

被引:32
作者
Droste, DW [1 ]
Decker, W [1 ]
Siemens, HJ [1 ]
Kaps, M [1 ]
SchulteAltedorneburg, G [1 ]
机构
[1] UNIV LUBECK,DEPT INTERNAL MED,D-23538 LUBECK,GERMANY
关键词
ultrasonics; transcranial Doppler sonography; emboli detection; chronobiology;
D O I
10.1080/01616412.1996.11740372
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Albeit still unproven, it is supposed that the presence and number of asymptomatic circulating cerebral microemboli detected by transcranial Doppler ultrasound (TCD) may be an indicator of stroke risk. Little research has been done to assess the reproducibility of these data and the required time for recording. We examined one middle cerebral artery in 7 subjects with carotid, aortic or cardiac embolic source for 24 h by TCD. Analysis for embolic signals was done off line completely blinded to the diagnosis and the time of the day during the recording. Embolic signals were found in all 7 subjects varying from 0 per h to 13 per h. Embolic signals occurred throughout the day with a nonsignificant tendency towards higher values in the early morning hours. Half an hour recording would not have been suitable to rule out or to confirm the presence of embolic signals as there were too many gaps between embolic signals of more than 1/2 h. One hour is the required minimum. Concerning the number of embolic signals, even a recording of four hours yielded variabilities of 0.25 and 8 embolic signals per hour in the same person. we recommend to perform follow-up studies the same time of the day. In patients with a low number of embolic signals longer recordings or a lower detection threshold with a higher number of detected embolic signals are necessary to compare frequencies of embolic signals.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 22 条
[1]   CLINICAL CORRELATES OF HIGH-INTENSITY TRANSIENT SIGNALS DETECTED ON TRANSCRANIAL DOPPLER SONOGRAPHY IN PATIENTS WITH CEREBROVASCULAR-DISEASE [J].
BABIKIAN, VL ;
HYDE, C ;
POCHAY, V ;
WINTER, MR .
STROKE, 1994, 25 (08) :1570-1573
[2]   THE EFFECT OF VELOCITY ON THE APPEARANCE OF EMBOLIC SIGNALS STUDIED IN TRANSCRANIAL DOPPLER MODELS [J].
DROSTE, DW ;
MARKUS, HS ;
NASSIRI, D ;
BROWN, MM .
STROKE, 1994, 25 (05) :986-991
[3]   THE EFFECT OF DIFFERENT SETTINGS OF ULTRASOUND PULSE AMPLITUDE, GAIN AND SAMPLE VOLUME ON THE APPEARANCE OF EMBOLI STUDIED IN A TRANSCRANIAL DOPPLER MODEL [J].
DROSTE, DW ;
MARKUS, HS ;
BROWN, MM .
CEREBROVASCULAR DISEASES, 1994, 4 (03) :152-156
[4]  
GALLERANI M, 1993, ACTA NEUROL SCAND, V87, P482
[5]   DETECTION OF INTRACRANIAL EMBOLI IN PATIENTS WITH CAROTID DISEASE [J].
GEORGIADIS, D ;
GROSSET, DG ;
QUIN, RO ;
NICHOL, JAR ;
BONE, I ;
LEES, KR .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (03) :309-314
[6]  
Grosset D G, 1994, J Heart Valve Dis, V3, P128
[7]   QUANTIFICATION OF ULTRASOUND EMBOLI SIGNALS IN PATIENTS WITH CARDIAC AND CAROTID DISEASE [J].
GROSSET, DG ;
GEORGIADIS, D ;
KELMAN, AW ;
LEES, KR .
STROKE, 1993, 24 (12) :1922-1924
[8]   CIRCADIAN VARIATIONS IN BLOOD-COAGULATION PARAMETERS, ALPHA-ANTITRYPSIN ANTIGEN AND PLATELET-AGGREGATION AND RETENTION IN CLINICALLY HEALTHY-SUBJECTS [J].
HAUS, E ;
CUSULOS, M ;
SACKETTLUNDEEN, L ;
SWOYER, J .
CHRONOBIOLOGY INTERNATIONAL, 1990, 7 (03) :203-216
[9]   CIRCADIAN VARIATIONS OF PLATELET AGGREGABILITY AND FIBRINOLYTIC-ACTIVITY IN PATIENTS WITH ISCHEMIC STROKE [J].
JOVICIC, A ;
IVANISEVIC, V ;
NIKOLAJEVIC, R .
THROMBOSIS RESEARCH, 1991, 64 (04) :487-491
[10]  
MARKUS HS, 1993, STROKE, V24, P1