Repeatability limits for measurement of coronary artery calcified plaque with cardiac CT in the multi-ethnic study of atherosclerosis

被引:28
作者
Chung, Hyoju [1 ]
McClelland, Robyn L. [1 ]
Katz, Ronit [1 ]
Carr, J. Jeffrey [2 ]
Budoff, Matthew J. [3 ]
机构
[1] Univ Washington, Collaborat Hlth Studies Coordinating Ctr, Dept Biostat, Seattle, WA 98115 USA
[2] Wake Forest Univ, Dept Radiol, Winston Salem, NC 27109 USA
[3] Harbor UCLA Med Ctr, Los Angeles Biomed Res Inst, Torrance, CA 90509 USA
关键词
cardiac CT; coronary artery calcification; detectable change; repeated scan; repeatability; repeatability limit;
D O I
10.2214/AJR.07.2726
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purposes of this study were to examine the repeatability of the findings of coronary artery calcification (CAC) measured with CT on repeated scans, to estimate 95% repeatability limits for CAC, and to use these limits to quantify detectable change in CAC over time. SUBJECTS AND METHODS. The Multi- Ethnic Study of Atherosclerosis is a prospective cohort study with 6,814 participants 45-84 years old and free of clinical cardiovascular disease at enrollment. Agreement for presence of CAC was assessed for 6,742 participants who had baseline replicate scans on which a CAC score of 0 indicated no coronary calcification. Among 3,380 participants with baseline CAC, the 95% repeatability limits were established with a quantile regression model. Detectable change in CAC during follow-up was defined by an increase or decrease beyond the baseline repeatability limit. RESULTS. At baseline, 274 (4.1%) of the rescan pairs were discordant (presence or absence of CAC). Greater body mass index was associated with a discordant pair (trend, p < 0.05). The upper 95% repeatability limits were (0.17 x Agatston score) + (4.89 x root Agatston score) + (0.44 x body mass index) - 10.84 for Agatston score and (0.16 x volumetric calcium score) + (4.30 x root volumetric calcium score) + (0.23 x body mass index) - 5.00 for volumetric calcium score. Rescan repeatability was comparable for electron beam and 4-MDCT scanners. At 2.5 years of average follow-up (range, 0.9-5.0 years), a detectable increase in Agatston and volumetric calcium scores was observed in 1,027 (36.3%) and 1,020 (36.0%), respectively, of 2,832 participants with baseline CAC. CONCLUSION. The repeatability limits derived can be used to evaluate whether an increase in CAC score exceeds that expected from measurement error alone.
引用
收藏
页码:W87 / W92
页数:6
相关论文
共 22 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Coronary artery calcification measured at electron-beam CT: Agreement in dual scan runs and change over time [J].
Bielak, LF ;
Sheedy, PF ;
Peyser, PA .
RADIOLOGY, 2001, 218 (01) :224-229
[3]   Multi-ethnic study of atherosclerosis: Objectives and design [J].
Bild, DE ;
Bluemke, DA ;
Burke, GL ;
Detrano, R ;
Roux, AVD ;
Folsom, AR ;
Greenland, P ;
Jacobs, DR ;
Kronmal, R ;
Liu, K ;
Nelson, JC ;
O'Leary, D ;
Saad, MF ;
Shea, S ;
Szklo, M ;
Tracy, RP .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2002, 156 (09) :871-881
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[6]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[7]   Calcified coronary artery plaque measurement with cardiac CT in population-based studies: Standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and Coronary Artery Risk Development in Young Adults (CARDIA) study [J].
Carr, JJ ;
Nelson, JC ;
Wong, ND ;
McNitt-Gray, M ;
Arad, Y ;
Jacobs, DR ;
Sidney, S ;
Bild, DE ;
Williams, OD ;
Detrano, RC .
RADIOLOGY, 2005, 234 (01) :35-43
[8]  
Chen Jersey, 2006, Circulation, V113, P125
[9]   How useful is computed tomography for screening for coronary artery disease? - Noninvasive screening for coronary artery disease with computed tomography is useful [J].
Clouse, ME .
CIRCULATION, 2006, 113 (01) :125-146
[10]   Coronary calcium measurements: Effect of CT scanner type and calcium measure on rescan reproducibility - MESA study [J].
Detrano, RC ;
Anderson, M ;
Nelson, J ;
Wong, ND ;
McNitt-Gray, M ;
Bild, DE .
RADIOLOGY, 2005, 236 (02) :477-484