MALDI-TOF mass spectrometry: Obtaining reliable mass spectra for insoluble carbonaceous pitches

被引:75
作者
Edwards, WF [1 ]
Jin, LW [1 ]
Thies, MC [1 ]
机构
[1] Clemson Univ, Dept Chem Engn, Ctr Adv Engn Fibers & Films, Clemson, SC 29634 USA
关键词
carbon precursor; mesophase pitch; petroleum pitch; mass spectrometry; chemical structure;
D O I
10.1016/S0008-6223(03)00386-5
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The insolubility of high molecular weight (MW) carbonaceous pitches (e.g. mesophases) in even aggressive solvents has always been a significant obstacle to their MW characterization. By using matrix-assisted, laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry with the matrix 7,7,8,8-tetracyanoquinodimethane (TCNQ), we are now able to obtain reproducible, highly resolved mass spectra for insoluble pitches. A solvent-free sample preparation technique was developed in which the matrix and pitch sample are combined and ground together to form a fine powder. We then use the high surface tension of water to create a thin uniform coating of the matrix-pitch mixture on the target cell. Laser power and pulsed ion extraction delay were both found to significantly alter the spectra obtained, and a procedure for optimizing each is described. Three carbonaceous pitches were evaluated: an anthracene pitch produced by thermal polymerization, a petroleum pitch similar to A-240 and produced by heat-soaking decant oil, and a high MW cut of this pitch produced by supercritical extraction. The anthracene pitch contained enough lower MW species to serve as a self-matrix, so no TCNQ addition was required. For the high MW cut of petroleum pitch, the use of TCNQ or dithranol revealed the presence of trimers and tetramers at MWs up to 1250 Da. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2761 / 2768
页数:8
相关论文
共 24 条
  • [11] Absolute calibration of size exclusion chromatography for coal derivatives through MALDI-ms
    Johnson, BR
    Bartle, KD
    Domin, M
    Herod, AA
    Kandiyoti, R
    [J]. FUEL, 1998, 77 (9-10) : 933 - 945
  • [12] LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS
    KARAS, M
    HILLENKAMP, F
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2299 - 2301
  • [13] MATRIX-ASSISTED LASER-DESORPTION IONIZATION (MALDI) MASS-SPECTROMETRY - A NOVEL ANALYTICAL TOOL IN MOLECULAR-BIOLOGY AND BIOTECHNOLOGY
    KAUFMANN, R
    [J]. JOURNAL OF BIOTECHNOLOGY, 1995, 41 (2-3) : 155 - 175
  • [14] MOLECULAR-WEIGHT ANALYSIS OF PITCHES AND POLYMERIC PITCHES BY GEL-PERMEATION CHROMATOGRAPHY
    LEWIS, IC
    PETRO, BA
    [J]. JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1976, 14 (08) : 1975 - 1985
  • [15] PREPARATION OF MESOPHASE PITCH FROM AROMATIC-HYDROCARBONS BY THE AID OF HF/BF3
    MOCHIDA, I
    SHIMIZU, K
    KORAI, Y
    OTSUKA, H
    SAKAI, Y
    FUJIYAMA, S
    [J]. CARBON, 1990, 28 (2-3) : 311 - 319
  • [16] CHARACTERIZATION OF POLYMERS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION-TIME OF FLIGHT MASS-SPECTROMETRY - END GROUP DETERMINATION AND MOLECULAR-WEIGHT ESTIMATES IN POLY(ETHYLENE GLYCOLS)
    MONTAUDO, G
    MONTAUDO, MS
    PUGLISI, C
    SAMPERI, F
    [J]. MACROMOLECULES, 1995, 28 (13) : 4562 - 4569
  • [17] Development of a nonisothermal Knudsen effusion method and application to PAH and cellulose tar vapor pressure measurement
    Oja, V
    Suuberg, EM
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4619 - 4626
  • [18] MALDI-TOF mass spectrometry of insoluble giant polycyclic aromatic hydrocarbons by a new method of sample preparation
    Przybilla, L
    Brand, JD
    Yoshimura, K
    Räder, HJ
    Müllen, K
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (19) : 4591 - 4597
  • [19] CARBONIZATION OF ANTHRACENE IN A BATCH REACTOR
    SCARONI, AW
    JENKINS, RG
    WALKER, PL
    [J]. CARBON, 1991, 29 (07) : 969 - 980
  • [20] A MALDI sample preparation method suitable for insoluble polymers
    Skelton, R
    Dubois, F
    Zenobi, R
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (07) : 1707 - 1710