Membrane inlet ion trap mass spectrometry for the direct measurement of dissolved gases in ecological samples

被引:19
作者
Cowie, G [1 ]
Lloyd, D [1 ]
机构
[1] Univ Wales, Microbiol Grp PABIO, Cardiff CF1 3TL, S Glam, Wales
关键词
denitrification; estuarine sediment; membrane inlet mass spectrometry; ion trap;
D O I
10.1016/S0167-7012(98)00090-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of an ion trap mass spectrometer with three different membrane inlet probes is described. Two methods of removing water from the sample are compared. One is the use of a PTFE-silicone rubber double membrane, PTFE is relatively impermeable to water and so reduces the amount entering with the gas sample (Probe A). The second is the use of a silicone rubber membrane covered long probe, which condenses water out of the sample (Probe B). Response times (100%) for dissolved N2O, O-2, Ar and CO2 without He in the chamber vary from between 158 and 684 s with Probe A. For the same probe with He, the response times were between 283 and 551 s. In the gas phase response times were between 99 and 153 s with He and 117 and 122 a without He. Probe B had 100% response of between 122 and 152 s for dissolved gases. Further extension of the probe by 2 m slowed response times as did increasing the ionisation time. Response times for Probe B increased to between 99 and 340 s when ionisation time increased from 1000 to 24 930 mu s. Plots of output against concentration showed the steepest line of response for the short single membrane covered probe with 1000 Cts ionisation time. Increasing the ionisation time, extending the probe and the use of a double membrane all reduced the gradient of output against concentration for every gas tested. In an intact sediment core, concentrations of O-2, N2O and CO2 rose at the start and the concentration of N-2 fell. As the disturbed sediment settled, this was reversed. The initial increase in O-2 concentration stimulated respiration and inhibited the final pathway in dentrification producing higher concentrations of N2O and reducing the concentration of N-2. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 13 条
[1]  
Benstead J, 1996, MICROBIAL ECOL, V31, P57, DOI 10.1007/BF00175075
[2]  
BENSTEAD J, 1994, FEMS MICROBIOL ECOL, V13, P233, DOI 10.1016/0168-6496(94)90017-5
[3]  
BIXLER HJ, 1971, SCI TECHNOLOGY POLYM, P1
[4]   ONLINE DETECTION OF VOLATILE ORGANIC-COMPOUNDS IN AIR AT PARTS-PER-TRILLION LEVELS BY MEMBRANE INTRODUCTION MASS-SPECTROMETRY [J].
CISPER, ME ;
GILL, CG ;
TOWNSEND, LE ;
HEMBERGER, PH .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1413-1417
[5]   A membrane-inlet mass spectrometer miniprobe for the direct simultaneous measurement of multiple gas species with spatial resolution of 1 mm [J].
Lloyd, D ;
Thomas, K ;
Price, D ;
ONeil, B ;
Oliver, K ;
Williams, TN .
JOURNAL OF MICROBIOLOGICAL METHODS, 1996, 25 (02) :145-151
[6]   THE PASTEUR EFFECT IN YEASTS - MASS-SPECTROMETRIC MONITORING OF OXYGEN-UPTAKE, AND CARBON-DIOXIDE AND ETHANOL-PRODUCTION [J].
LLOYD, D ;
JAMES, CJ .
FEMS MICROBIOLOGY LETTERS, 1987, 42 (01) :27-31
[7]   QUADRUPOLE MASS-SPECTROMETRY IN THE MONITORING AND CONTROL OF FERMENTATIONS [J].
LLOYD, D ;
BOHATKA, S ;
SZILAGYI, J .
BIOSENSORS, 1985, 1 (02) :179-212
[8]  
LLOYD D, 1986, FEMS MICROBIOL ECOL, V38, P11, DOI 10.1111/j.1574-6968.1986.tb01933.x
[9]  
LLOYD D, 1987, MASS SPECTROMETRY BI, P91
[10]  
SCOTT IR, 1983, EUR J APPL MICROBIOL, V18, P1