Quantitative analysis of small pharmaceutical drugs using a high repetition rate laser matrix-assisted laser/desorption ionization source

被引:95
作者
Hatsis, P
Brombacher, S
Corr, J
Kovarik, P
Volmer, DA
机构
[1] CNR, Inst Marine Biosci, Halifax, NS B3H 3Z1, Canada
[2] MDS Sciex, Concord, ON L4K 4V8, Canada
关键词
D O I
10.1002/rcm.1192
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a high repetition rate laser matrix-assisted laser desorption/ionization (MALDI) source is studied on a quadrupole-time-of-flight (QqTOF) and a triple quadrupole (QqQ) mass spectrometer for rapid quantification of small pharmaceutical drugs. The high repetition rate laser allows an up to 100-fold higher pulse frequency as compared with regular MALDI lasers, resulting in much larger sample throughput and number of accumulated spectra. This increases the reproducibility of signal intensities considerably, with average values being around 5% relative standard deviation after taking into account the area ratio of the analyte to an internal standard. Experiments were conducted in MS/MS mode to circumvent the large chemical background due to MALDI matrix ions in the low mass range. The dynamic range of calibration curves on the QqTOF mass spectrometer extended over at least two orders of magnitude, whereas on the QqQ it extended over at least three orders of magnitude. Detection limits ranged from 60-400 pg/muL on the QqTOF and from 6-70pg/muL on the QqQ for a series of benzodiazepines. The benzodiazepine content of commercial pill formulations was quantified, and less than 5% error was obtained between the present method and the manufacturer's certified values. Furthermore, a high sample throughput was achieved with this method, so that a single MALDI spot could be quantitatively scanned in as little as 15 s, and an entire 96-well MALDI plate in 24 min. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:2303 / 2309
页数:7
相关论文
共 31 条
[1]  
BROMIRSKI M, 1999, P 4M ASMS C MASS SPE
[2]   Quantitative estimation of geometric isomers by post-source decay MALDI MS [J].
Cheng, Y ;
Hercules, DM .
MICROCHEMICAL JOURNAL, 2002, 72 (03) :255-267
[3]   Small molecule analysis by MALDI mass spectrometry [J].
Cohen, LH ;
Gusev, AI .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (07) :571-586
[4]  
Devore JL., 2000, Probability and statistics for engineering and the sciences
[5]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR-WEIGHT COMPOUNDS OF BIOLOGICAL INTEREST BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION [J].
DUNCAN, MW ;
MATANOVIC, G ;
CERPAPOLJAK, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (12) :1090-1094
[6]   IMPROVEMENT OF SIGNAL REPRODUCIBILITY AND MATRIX/COMATRIX EFFECTS IN MALDI ANALYSIS [J].
GUSEV, AI ;
WILKINSON, WR ;
PROCTOR, A ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1034-1041
[7]   Interfacing matrix-assisted laser desorption/ionization mass spectrometry with column and planar separations [J].
Gusev, AI .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :691-700
[8]  
Hensel RR, 1997, RAPID COMMUN MASS SP, V11, P1785
[9]   Optimisation of the quantitative determination of chlormequat by matrix-assisted laser desorption/ionisation mass spectrometry [J].
Horak, J ;
Werther, W ;
Schmid, ER .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (04) :241-248
[10]   Feasibility of atmospheric pressure desorption/ionization on silicon mass spectrometry in analysis of drugs [J].
Huikko, K ;
Östman, P ;
Sauber, C ;
Mandel, F ;
Grigoras, K ;
Franssila, S ;
Kotiaho, T ;
Kostiainen, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (12) :1339-1343