Heterogeneous distribution of pulmonary ventilation in intensive care patients detected by functional electrical impedance tomography

被引:11
作者
Frerichs, I [1 ]
Golisch, W [1 ]
Hahn, G [1 ]
Kurpitz, M [1 ]
Burchardi, H [1 ]
Hellige, G [1 ]
机构
[1] Univ Gottingen, Ctr Anesthesiol Emergency & Intens Care Med, Dept Anesthesiol Res, D-37075 Gottingen, Germany
关键词
D O I
10.1177/088506669801300404
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Electrical impedance tomography (EIT) is a new noninvasive imaging technique which utilizes the different electrical properties of biological tissues to produce cross-sectional images of selected parts of the body. When applied on the thorax, the cyclic fluctuations of electrical impedance of the lung tissue, associated with different air contents of the lungs in the course of the respiratory cycle, can be used to generate derived EIT tomograms which represent the spatial distribution of ventilation in the chosen transverse plane. The corresponding evaluation technique, the functional EIT, was used for the first time to follow the regional ventilation in three intensive care patients. The method was shown (1) to identify; the redistribution of inspired air in the lungs associated with controlled ventilation in a patient undergoing elective laparotomy,, (2) to follow the improvement of locally impaired lung ventilation in the course of severe pneumonia, and (3) to detect regional reduction of ventilation due ti, lobar atelectasis with stasis pneumonia in a patient with bronchial carcinoma.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 15 条
[1]   QUANTIFICATION IN IMPEDANCE IMAGING [J].
BARBER, DC .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 :45-56
[2]  
Brown B H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P91, DOI 10.1088/0143-0815/8/4A/012
[3]  
BROWN BH, 1987, MED PROG TECHNOL, V13, P69
[4]   CLINICAL-APPLICATIONS OF ELECTRICAL-IMPEDANCE TOMOGRAPHY IN THE MONITORING OF CHANGES IN INTRATHORACIC FLUID VOLUMES [J].
CAMPBELL, JH ;
HARRIS, ND ;
ZHANG, F ;
BROWN, BH ;
MORICE, AH .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 :A217-A222
[5]   Gravity-dependent phenomena in lung ventilation determined by functional EIT [J].
Frerichs, I ;
Hahn, G ;
Hellige, G .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A149-A157
[6]  
Frerichs I., 1997, Atemwegs- und Lungenkrankheiten, V23, P448
[7]   EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE ON REGIONAL DISTRIBUTION OF TIDAL VOLUME AND RECRUITMENT IN ADULT-RESPIRATORY-DISTRESS-SYNDROME [J].
GATTINONI, L ;
PELOSI, P ;
CROTTI, S ;
VALENZA, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) :1807-1814
[8]   ANALYSIS OF LUNG DENSITY BY COMPUTED-TOMOGRAPHY BEFORE AND DURING GENERAL-ANESTHESIA [J].
HACHENBERG, T ;
LUNDQUIST, H ;
TOKICS, L ;
BRISMAR, B ;
HEDENSTIERNA, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (06) :549-555
[9]   Local mechanics of the lung tissue determined by functional EIT [J].
Hahn, G ;
Frerichs, I ;
Kleyer, M ;
Hellige, G .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A159-A166
[10]   CHANGES IN THE THORACIC IMPEDANCE DISTRIBUTION UNDER DIFFERENT VENTILATORY CONDITIONS [J].
HAHN, G ;
SIPINKOVA, I ;
BAISCH, F ;
HELLIGE, G .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A161-A173