Picogram levels of antibodies against the protective antigen (PA) of Bacillus anthracis were detected in an automated electrochemical sandwich-type enzyme-linked immunosorbant assay. The antibodies were captured and detected using an 8 x 3 array of 50-mu m-diameter cavities. The reagent and sample volumes were as low as 200 nL in a less than 25-min assay from capture to signal generation. The electrochemical detection of the antibodies was demonstrated at 0.05-10 mu g/mL containing only 10-5,000 pg antibodies. The limit of detection is 10 fg for a 200-nL sample. Detection of anti-PA immunoglobulin G performed in spiked normal human serum and fresh whole human blood did not show a significant difference from detection in a buffer. The initial automation of the assay involved the use of a digital syringe pump for the delivery of reagents to the capture surface.
引用
收藏
页码:507 / 515
页数:9
相关论文
共 28 条
[1]   Self-contained microelectrochemical immunoassay for small volumes using mouse IgG as a model system [J].
Aguilar, ZP ;
Vandaveer, WR ;
Fritsch, I .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3321-3329
[2]  
AGUILAR ZP, 2006, ECS T, V3, P125
[3]   Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins [J].
Biagini, RE ;
Sammons, DL ;
Smith, JP ;
MacKenzie, BA ;
Striley, CAF ;
Semenova, V ;
Steward-Clark, E ;
Stamey, K ;
Freeman, AE ;
Quinn, CP ;
Snawder, JE .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2004, 11 (01) :50-55
[4]   Simultaneous measurement of specific serum IgG responses to five select agents [J].
Biagini, RE ;
Sammons, DL ;
Smith, JP ;
MacKenzie, BA ;
Striley, CAF ;
Robertson, SA ;
Snawder, JE ;
Quinn, CP .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (04) :1027-1034
[5]  
BUTLER JE, 1991, IMMUNOCHEMISTRY SOLI, P319
[6]   POTENTIAL-DEPENDENT STABILITY OF SELF-ASSEMBLED ORGANOTHIOLS ON GOLD ELECTRODES IN METHYLENE-CHLORIDE [J].
EVERETT, WR ;
WELCH, TL ;
REED, L ;
FRITSCHFAULES, I .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :292-298
[7]   FACTORS THAT INFLUENCE THE STABILITY OF SELF-ASSEMBLED ORGANOTHIOLS ON GOLD UNDER ELECTROCHEMICAL CONDITIONS [J].
EVERETT, WR ;
FRITSCHFAULES, I .
ANALYTICA CHIMICA ACTA, 1995, 307 (2-3) :253-268
[8]  
Guidi-Rontani C., 2002, VVolume 271, P115
[9]   Microcavities containing individually addressable recessed microdisk and tubular nanoband electrodes [J].
Henry, CS ;
Fritsch, I .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (09) :3367-3373
[10]   Microfabricated recessed microdisk electrodes: Characterization in static and convective solutions [J].
Henry, CS ;
Fritsch, I .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :550-556