A comparison of intratumoural indices of blood flow velocity and impedance for the diagnosis of ovarian cancer

被引:36
作者
Tailor, A [1 ]
Jurkovic, D [1 ]
Bourne, TH [1 ]
Natucci, M [1 ]
Collins, WP [1 ]
Campbell, S [1 ]
机构
[1] UNIV LONDON KINGS COLL,SCH MED & DENT,ACAD DEPT OBSTET & GYNAECOL,LONDON WC2R 2LS,ENGLAND
关键词
Doppler ultrasound; adnexal masses; pulsatility index; resistance index; peak systolic velocity; time-averaged maximum velocity; ovarian cancer;
D O I
10.1016/0301-5629(96)00087-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim was to assess the value of blood flow velocity indices in an ultrasound-based test to discriminate between malignant and benign adnexal tumours. Fifty-one women (35 premenopausal and 16 postmenopausal) with persistent adnexal masses were scanned prior to surgery using transvaginal sonography with colour Doppler imaging. Intratumoural flow velocity waveforms obtained by pulsed Doppler sonography were used to determine the time averaged maximum velocity (TAMXV), peak systolic velocity (PSV), pulsatility index (PI) and resistance index (RI). The tumours were classified by histologic criteria (42 benign, 1 borderline and 8 malignant tumours). Two of the malignant and the single borderline tumour were stage I, five were stage III and one was stage IV. Detectable blood flow signals were found in all malignant and borderline tumours and in 33 of 42 (78.6%) of the benign tumours. TAMXV was the best parameter for discrimination of benign and malignant adnexal pathology and at a cut-off value of TAMXV greater than or equal to 12 cm/s to indicate malignancy, the sensitivity and specificity were 88.9% and 81.0%, respectively. At the same sensitivity level, this gave a better specificity than the PI less than or equal to 0.90 (specificity 61.9%, P = 0.036), RI less than or equal to 0.60 (specificity 54.8%, P = 0.010) and PSV greater than or equal to 16 cm/s (specificity 71.4%, P = 0.121). Discrimination between benign and malignant tumours was improved further by using two criteria rather than one. When the two criteria of a TAMXV of greater than or equal to 12 cm/s and a PI less than or equal to 1.0 were applied simultaneously, the tumours could be characterised with a sensitivity of 88.9% and a specificity of 88.1%. Therefore, intratumoural PSV and TAMXV could be used to discriminate between benign and malignant adnexal tumours better than values for PI and RI. The best discrimination was achieved by using a combination of cut-off values for velocity and impedance parameters as two criteria to define malignancy.
引用
收藏
页码:837 / 843
页数:7
相关论文
共 30 条
[1]  
[Anonymous], 1973, INT HISTOLOGICAL CLA
[2]  
BECK JR, 1986, ARCH PATHOL LAB MED, V110, P13
[3]  
BLAND M, 1992, DOPPLER ULTRASOUND P, P17
[4]   TRANS-VAGINAL COLOR FLOW IMAGING - A POSSIBLE NEW SCREENING TECHNIQUE FOR OVARIAN-CANCER [J].
BOURNE, T ;
CAMPBELL, S ;
STEER, C ;
WHITEHEAD, MI ;
COLLINS, WP .
BRITISH MEDICAL JOURNAL, 1989, 299 (6712) :1367-1370
[5]   Ultrasound studies of vascular and morphological changes in the human corpus luteum during the menstrual cycle [J].
Bourne, TH ;
Hagstrom, HG ;
Hahlin, M ;
Josefsson, B ;
Granberg, S ;
Hellberg, P ;
Hamberger, L ;
Collins, WP .
FERTILITY AND STERILITY, 1996, 65 (04) :753-758
[6]  
BROMLEY B, 1994, OBSTET GYNECOL, V83, P434
[7]  
CAMPBELL S, 1993, FERTIL STERIL, V60, P433
[8]  
CARTER J, 1994, OBSTET GYNECOL, V83, P125
[9]   BLOOD-FLOW CHARACTERISTICS OF OVARIAN-TUMORS - IMPLICATIONS FOR OVARIAN-CANCER SCREENING [J].
CARTER, JR ;
LAU, M ;
FOWLER, JM ;
CARLSON, JW ;
CARSON, LF ;
TWIGGS, LB .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 172 (03) :901-907
[10]   COLOR DOPPLER ULTRASONOGRAPHY AND SERUM CA-125 IN THE DIFFERENTIATION OF BENIGN AND MALIGNANT OVARIAN-TUMORS [J].
CHOU, CY ;
CHANG, CH ;
YAO, BL ;
KUO, HC .
JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (08) :491-496