A comparison of intratumoural indices of blood flow velocity and impedance for the diagnosis of ovarian cancer

被引:36
作者
Tailor, A [1 ]
Jurkovic, D [1 ]
Bourne, TH [1 ]
Natucci, M [1 ]
Collins, WP [1 ]
Campbell, S [1 ]
机构
[1] UNIV LONDON KINGS COLL,SCH MED & DENT,ACAD DEPT OBSTET & GYNAECOL,LONDON WC2R 2LS,ENGLAND
关键词
Doppler ultrasound; adnexal masses; pulsatility index; resistance index; peak systolic velocity; time-averaged maximum velocity; ovarian cancer;
D O I
10.1016/0301-5629(96)00087-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim was to assess the value of blood flow velocity indices in an ultrasound-based test to discriminate between malignant and benign adnexal tumours. Fifty-one women (35 premenopausal and 16 postmenopausal) with persistent adnexal masses were scanned prior to surgery using transvaginal sonography with colour Doppler imaging. Intratumoural flow velocity waveforms obtained by pulsed Doppler sonography were used to determine the time averaged maximum velocity (TAMXV), peak systolic velocity (PSV), pulsatility index (PI) and resistance index (RI). The tumours were classified by histologic criteria (42 benign, 1 borderline and 8 malignant tumours). Two of the malignant and the single borderline tumour were stage I, five were stage III and one was stage IV. Detectable blood flow signals were found in all malignant and borderline tumours and in 33 of 42 (78.6%) of the benign tumours. TAMXV was the best parameter for discrimination of benign and malignant adnexal pathology and at a cut-off value of TAMXV greater than or equal to 12 cm/s to indicate malignancy, the sensitivity and specificity were 88.9% and 81.0%, respectively. At the same sensitivity level, this gave a better specificity than the PI less than or equal to 0.90 (specificity 61.9%, P = 0.036), RI less than or equal to 0.60 (specificity 54.8%, P = 0.010) and PSV greater than or equal to 16 cm/s (specificity 71.4%, P = 0.121). Discrimination between benign and malignant tumours was improved further by using two criteria rather than one. When the two criteria of a TAMXV of greater than or equal to 12 cm/s and a PI less than or equal to 1.0 were applied simultaneously, the tumours could be characterised with a sensitivity of 88.9% and a specificity of 88.1%. Therefore, intratumoural PSV and TAMXV could be used to discriminate between benign and malignant adnexal tumours better than values for PI and RI. The best discrimination was achieved by using a combination of cut-off values for velocity and impedance parameters as two criteria to define malignancy.
引用
收藏
页码:837 / 843
页数:7
相关论文
共 30 条
[21]   INTRAOBSERVER AND INTEROBSERVER RELIABILITY OF THE PULSATILITY INDEX CALCULATED FROM PULSED DOPPLER FLOW VELOCITY WAVE-FORMS IN 3 FETAL VESSELS [J].
SCHERJON, SA ;
KOK, JH ;
OOSTING, H ;
ZONDERVAN, HA .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (02) :134-138
[22]   REVISED FIGO STAGING FOR GYNECOLOGICAL CANCER [J].
SHEPHERD, JH .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (08) :889-892
[23]   TRANSVAGINAL GRAY-SCALE AND DOPPLER ULTRASOUND EXAMINATIONS OF THE UTERUS AND OVARIES IN HEALTHY POSTMENOPAUSAL WOMEN [J].
SLADKEVICIUS, P ;
VALENTIN, L ;
MARSAL, K .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 6 (02) :81-90
[24]   DIFFERENTIATION OF BENIGN AND MALIGNANT ADNEXAL MASSES - RELATIVE VALUE OF GRAY-SCALE, COLOR DOPPLER, AND SPECTRAL DOPPLER SONOGRAPHY [J].
STEIN, SM ;
LAIFERNARIN, S ;
JOHNSON, MB ;
ROMAN, LD ;
MUDERSPACH, LI ;
TYSZKA, JM ;
RALLS, PW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (02) :381-386
[25]   CORRELATION OF DOPPLER ULTRASOUND TUMOR SIGNALS WITH NEOVASCULAR MORPHOLOGIC FEATURES [J].
TAYLOR, KJW ;
RAMOS, I ;
CARTER, D ;
MORSE, SS ;
SNOWER, D ;
FORTUNE, K .
RADIOLOGY, 1988, 166 (01) :57-62
[26]   BLOOD-FLOW IN BENIGN OVARIAN-TUMORS AND NORMAL OVARIES DURING THE FOLLICULAR PHASE [J].
TEKAY, A ;
JOUPPILA, P .
OBSTETRICS AND GYNECOLOGY, 1995, 86 (01) :55-59
[27]   TRANSVAGINAL ULTRASONOGRAPHIC CHARACTERIZATION OF OVARIAN MASSES BY MEANS OF COLOR FLOW-DIRECTED DOPPLER MEASUREMENTS AND A MORPHOLOGIC SCORING SYSTEM [J].
TIMORTRITSCH, IE ;
LERNER, JP ;
MONTEAGUDO, A ;
SANTOS, R .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 168 (03) :909-913
[28]  
VALENTIN L, 1994, OBSTET GYNECOL, V83, P425
[29]  
WEINER Z, 1992, OBSTET GYNECOL, V79, P159
[30]   COLOR DOPPLER ULTRASOUND IN THE PREOPERATIVE ASSESSMENT OF ADNEXAL MASSES [J].
ZANETTA, G ;
VERGANI, P ;
LISSONI, A .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1994, 73 (08) :637-641