Changes in piCO2 reflect splanchnic mucosal ischaemia more reliably than changes in pHi during haemorrhagic shock

被引:14
作者
Meisner, FG
Habler, OP
Kemming, GI
Kleen, MS
Pape, A
Messmer, K
机构
[1] Univ Munich Clin, Inst Surg Res, D-81377 Munich, Germany
[2] Univ Munich, Clin Anaesthesiol, Grosshedern, Germany
关键词
gastric tonometry; pH(i); p(i)CO(2); H+] gap; pCO(2) gap; haemorrhagic shock; shock; monitoring; metabolism; gastric mucosa; blood gas analysis;
D O I
10.1007/s004230100230
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Gastric tonometry is intended to reveal alterations in splanchnic perfusion and oxygenation. Based on the tonometric measurement of gastric mucosal partial pressure of carbon dioxide (PCO2) and the simultaneous determination of arterial blood gas parameters (bicarbonate concentration [HCO3-] pH and pCO(2)), several parameters can be calculated. Aims: To identify the most suitable tonometric parameter [gastric mucosal pH (pH(i)), intramucosal PCO2 (p(i)CO(2)), the difference between tonometric and arterial pCO(2) concentrations (PCO2 gap), [H+] gap] that reliably reflects gastric hypoperfusion and hypoxia during severe haemorrhagic shock. Design: Randomised, controlled experimental study. Methods: An artificial stenosis of the left anterior descending coronary artery (LAD) was induced. Subsequently, the animals were haemorrhaged to a mean arterial pressure of 45 mmHg, which was maintained for 60 min. Measurements and main results: Tonometric measurements were performed in 17 land-race pigs before and after induction of LAD stenosis and after haemorrhagic shock. P values obtained using the Wilcoxon signed-rank testing were used to compare the level of significance for the tonometric parameters and the corresponding arterial blood gas values [arterial pCO(2) (PaCO2), [HCO3-], arterial pH (pH,)]. While induction of critical coronary stenosis did not provoke any changes, all parameters changed significantly during haemorrhagic shock. The lowest P value was found for pHi (P=0.00013) followed by [H+ gap] (P=0.0005). P values higher by a factor of ten were found for PCO2 gap (P=0.00119) and were highest for PiCO2 (P=0.00562). P values of the corresponding arterial blood gas parameters were lower by a factor of ten than the P value of PiCO2. Conclusion: pH(i), PCO2 gap and [H+] gap are considerably influenced by changes of systemic arterial blood gas values. This is demonstrated by lower P values of the corresponding arterial blood gas values in comparison with PiCO2. Therefore pHi, PCO2 gap and [H+] gap seem to indicate more likely systemic changes, whereas PiCO2 appears to reflect disturbances of regional gastric tissue perfusion and oxygenation more reliably than any other derived tonometric parameter.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 33 条
[1]   VALIDATION OF TONOMETRIC MEASUREMENT OF GUT INTRAMURAL PH DURING ENDOTOXEMIA AND MESENTERIC OCCLUSION IN PIGS [J].
ANTONSSON, JB ;
BOYLE, CC ;
KRUITHOFF, KL ;
WANG, HL ;
SACRISTAN, E ;
ROTHSCHILD, HR ;
FINK, MP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (04) :G519-G523
[2]  
ANTONSSON JB, 1991, ACTA CHIR-EUR J SURG, V157, P3
[3]   INTRALUMINAL PCO2 - A RELIABLE INDICATOR OF INTESTINAL ISCHEMIA [J].
BASS, BL ;
SCHWEITZER, EJ ;
HARMON, JW ;
KRAIMER, J .
JOURNAL OF SURGICAL RESEARCH, 1985, 39 (04) :351-360
[5]   Gastric tonometry accurately predicts mortality in experimental peritonitis in both laparoscopic and conventional surgery [J].
Bloechle, C ;
Strate, T ;
Emmermann, A ;
Schneider, C ;
Mack, D ;
Wolf, M ;
Zornig, C ;
Broelsch, CE ;
Izbicki, JR .
LANGENBECKS ARCHIVES OF SURGERY, 1999, 384 (01) :76-83
[6]  
BORTZ J, 1995, KURZGEFASSTE STAT KL
[7]   COMPARISON OF CLINICAL INFORMATION GAINED FROM ROUTINE BLOOD-GAS ANALYSIS AND FROM GASTRIC TONOMETRY FOR INTRAMURAL PH [J].
BOYD, O ;
MACKAY, CJ ;
LAMB, G ;
BLAND, JM ;
GROUNDS, RM ;
BENNETT, ED .
LANCET, 1993, 341 (8838) :142-146
[8]   Usefulness of gastric intramucosal pH for monitoring hemodynamic complications in critically ill children [J].
Calvo, C ;
Ruza, F ;
Lopez-Herce, J ;
Dorao, P ;
Arribas, N ;
Alvarado, F .
INTENSIVE CARE MEDICINE, 1997, 23 (12) :1268-1274
[9]   Does gastric tonometry monitor splanchnic perfusion? [J].
Creteur, J ;
De Backer, D ;
Vincent, JL .
CRITICAL CARE MEDICINE, 1999, 27 (11) :2480-2484
[10]   GASTRIC INTRAMURAL PCO2 DURING PERITONITIS AND SHOCK [J].
DESAI, VS ;
WEIL, MH ;
TANG, WC ;
YANG, G ;
BISERA, J .
CHEST, 1993, 104 (04) :1254-1258