Does gastric tonometry monitor splanchnic perfusion?

被引:39
作者
Creteur, J [1 ]
De Backer, D [1 ]
Vincent, JL [1 ]
机构
[1] Free Univ Brussels, Hop Erasme, Dept Intens Care, B-1070 Brussels, Belgium
关键词
gut mucosal blood flow; gastric intramucosal pH; hepatosplanchnic blood flow; mesenteric blood flow; splanchnic ischemia; monitoring; gastric tonometry; sepsis; oxygen supply; tissue oxygenation;
D O I
10.1097/00003246-199911000-00026
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To define whether the gastric mucosal-arterial PCO2 gradient (PCO2 gap) reliably reflects hepatosplanchnic oxygenation in septic patients, Design: Prospective observational clinical study, Setting: An adult, 31-bed medical/surgical department of intensive care of a university hospital, Patients: A total of 36 hemodynamically stable, invasively monitored, mechanically ventilated, sedated, paralyzed patients with severe sepsis, Interventions: In each patient, hepatosplanchnic blood flow was determined by the continuous indocyanine green infusion technique and gastric mucosal PCO2 by the saline tonometry technique, Suprahepatic venous blood oxygen saturation and PCO2 also were measured, The mesenteric veno-arterial PCO2 gradient was determined as the difference between the suprahepatic venous blood PCO2 and the arterial blood PCO2. Measurements and Main Results: There were significant cor-relations between the hepatosplanchnic blood flow and the suprahepatic venous blood oxygen saturation (r(2) = .56; p < .01), between the hepatosplanchnic blood flow and the mesenteric veno-arterial PCO2 gradient (r(2) = .55; p < .01), and also between the suprahepatic venous blood oxygen saturation and the mesenteric veno-arterial PCO2 gradient (r(2) = .64; p < .01), There was no statistically significant correlation between the PCO2 gap and the hepatosplanchnic blood flow, the suprahepatic venous blood oxygen saturation or the mesenteric veno-arterial PCO2 gradient. Conclusions: In stable septic patients, the PCO2 gap is not correlated with global indexes of gut oxygenation, The interpretation of PCO2 gap is more complex than previously thought.
引用
收藏
页码:2480 / 2484
页数:5
相关论文
共 34 条
[1]  
ANTONSSON JB, 1990, AM J PHYSIOL, V259, P519
[2]   ALTERATIONS IN LIVER HEMODYNAMICS IN AN INTACT PORCINE MODEL OF ENDOTOXIN-SHOCK [J].
AYUSE, T ;
BRIENZA, N ;
REVELLY, JP ;
ODONNELL, CP ;
BOITNOTT, JK ;
ROBOTHAM, JL .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (03) :H1106-H1114
[3]   VENOARTERIAL CARBON-DIOXIDE GRADIENT IN HUMAN SEPTIC SHOCK [J].
BAKKER, J ;
VINCENT, JL ;
GRIS, P ;
LEON, M ;
COFFERNILS, M ;
KAHN, RJ .
CHEST, 1992, 101 (02) :509-515
[4]   AMERICAN-COLLEGE OF CHEST PHYSICIANS SOCIETY OF CRITICAL CARE MEDICINE CONSENSUS CONFERENCE - DEFINITIONS FOR SEPSIS AND ORGAN FAILURE AND GUIDELINES FOR THE USE OF INNOVATIVE THERAPIES IN SEPSIS [J].
BONE, RC ;
BALK, RA ;
CERRA, FB ;
DELLINGER, RP ;
FEIN, AM ;
KNAUS, WA ;
SCHEIN, RMH ;
SIBBALD, WJ ;
ABRAMS, JH ;
BERNARD, GR ;
BIONDI, JW ;
CALVIN, JE ;
DEMLING, R ;
FAHEY, PJ ;
FISHER, CJ ;
FRANKLIN, C ;
GORELICK, KJ ;
KELLEY, MA ;
MAKI, DG ;
MARSHALL, JC ;
MERRILL, WW ;
PRIBBLE, JP ;
RACKOW, EC ;
RODELL, TC ;
SHEAGREN, JN ;
SILVER, M ;
SPRUNG, CL ;
STRAUBE, RC ;
TOBIN, MJ ;
TRENHOLME, GM ;
WAGNER, DP ;
WEBB, CD ;
WHERRY, JC ;
WIEDEMANN, HP ;
WORTEL, CH .
CRITICAL CARE MEDICINE, 1992, 20 (06) :864-874
[5]   EVIDENCE FOR A COUNTERCURRENT EXCHANGER IN THE INTESTINAL VILLI OF SUCKLING SWINE [J].
BUSTAMANTE, SA ;
JODAL, M ;
NILSSON, NJ ;
LUNDGREN, O .
ACTA PHYSIOLOGICA SCANDINAVICA, 1989, 137 (02) :207-213
[6]   Monitoring gastric mucosal carbon dioxide pressure using gas tonometry: In vitro and in vivo validation studies [J].
Creteur, J ;
DeBacker, D ;
Vincent, JL .
ANESTHESIOLOGY, 1997, 87 (03) :504-510
[7]   GASTRIC-MUCOSAL PH AS A PROGNOSTIC INDEX OF MORTALITY IN CRITICALLY ILL PATIENTS [J].
DOGLIO, GR ;
PUSAJO, JF ;
EGURROLA, MA ;
BONFIGLI, GC ;
PARRA, C ;
VETERE, L ;
HERNANDEZ, MS ;
FERNANDEZ, S ;
PALIZAS, F ;
GUTIERREZ, G .
CRITICAL CARE MEDICINE, 1991, 19 (08) :1037-1040
[8]   BACK-DIFFUSION OF CO2 AND ITS INFLUENCE ON THE INTRAMURAL PH IN GASTRIC-MUCOSA [J].
FIDDIANGREEN, RG ;
PITTENGER, G ;
WHITEHOUSE, WM .
JOURNAL OF SURGICAL RESEARCH, 1982, 33 (01) :39-48
[10]   COMBINED MEASUREMENTS OF BLOOD LACTATE CONCENTRATIONS AND GASTRIC INTRAMUCOSAL PH IN PATIENTS WITH SEVERE SEPSIS [J].
FRIEDMAN, G ;
BERLOT, G ;
KAHN, RJ ;
VINCENT, JL .
CRITICAL CARE MEDICINE, 1995, 23 (07) :1184-1193