A YAP camera 40 x 40 mm2 with fast readout electronics

被引:2
作者
de Notaristefani, F [1 ]
Iacopi, F
Leonetti, C
Maini, CL
Malatesta, T
Mali, P
Semprebene, A
Torrioli, S
Tuma, L
Vittori, F
机构
[1] Univ Rome, Dept Phys, Ist Nazl Fis Nucl, Sect Rome, Rome, Italy
[2] Univ Roma La Sapienza, Dept Phys, Ist Nazl Fis Nucl, Sect Rome, Rome, Italy
[3] Ist Regina Elena, Expt Chemotherapy Lab, I-00161 Rome, Italy
[4] Ist Regina Elena, Div Nucl Med, I-00161 Rome, Italy
[5] Ist Regina Elena, Med Phys Lab, I-00161 Rome, Italy
[6] Preciosa Crytur, Turnov, Czech Republic
[7] Tescan, Brno, Czech Republic
关键词
PSPMT; radiopharmaceuticals; resistive chain readout; YAP : Ce;
D O I
10.1109/23.725268
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Previous papers have already demonstrated the suitability, for single-photon emission computed tomography (SPECT) tracers biodistribution studies on small animals, of a miniature gamma camera composed by a YAP:Ce scintillating array 4 x 4 x 1 cm(3) coupled to a 3-in Hamamatsu crossed-wire anode position sensitive photomultiplier (PSPMT). Some modifications have been applied to the imaging system readout in order to adapt its utilization for specific purposes (i,e., SPECT radiopharmaceutical testing) and to reduce construction costs so that a larger scale production may be feasible. In particular, the system introduced here is based on a resistive chain readout and an integrated acquisition electronics. The intrinsic performance of this new version has been analyzed and compared to the previous system, which had a single-wire readout, Results showed that the basic characteristics of the imaging system remain substantially unchanged in this simplified version, while a faster count rate is achieved. A test on a biological sample performed with the YAP camera both in single-mire and in resistive chain readout modality is also presented, which shows the system high performance in comparison to the Anger camera.
引用
收藏
页码:2302 / 2308
页数:7
相关论文
共 11 条
[1]  
Barone LM, 1995, NUCL PHYS B, P729, DOI 10.1016/0920-5632(95)00608-7
[2]   YAP MULTICRYSTAL GAMMA-CAMERA PROTOTYPE [J].
BLAZEK, K ;
DENOTARISTEFANI, F ;
MALY, P ;
PANI, R ;
PELLEGRINI, R ;
PERGOLA, A ;
SCOPINARO, F ;
SOLURI, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (05) :1474-1482
[3]   First results from a YAP:Ce gamma camera for small animal studies [J].
deNotaristefani, F ;
Pani, R ;
Scopinaro, F ;
Barone, LM ;
Blazek, K ;
DeVincentis, G ;
Malatesta, T ;
Maly, P ;
Pellegrini, R ;
Pergola, A ;
Soluri, A ;
Vittori, F .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) :3264-3271
[4]  
IACOPI F, 1997, 1084 INFN NAT I NUCL
[5]   Energy response and resolution of YAP:Ce matrix for imaging applications in nuclear medicine [J].
Malatesta, T ;
Vittori, F ;
de Notaristefani, F ;
Pani, R .
NUCLEAR PHYSICS B, 1998, :658-665
[6]  
MOORE SC, 1992, EUR J NUCL MED, V19, P138, DOI 10.1007/BF00184130
[7]  
NATALI PG, 1983, J NATL CANCER I, V71, P439
[8]   Scintillating array gamma camera for clinical use [J].
Pani, R ;
Pellegrini, R ;
Scopinaro, F ;
Soluri, A ;
DeVincentis, G ;
Pergola, A ;
Iacopi, F ;
Corona, A ;
Grammatico, A ;
Filippi, S ;
Ballesio, PL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :295-298
[9]  
PANI R, 1995, P IEEE NSS MIC SAN F
[10]  
TORRIOLI S, 1996, THESIS SAPIENZA U RO