Factors affecting the displacement force exerted on a stent graft after AAA repair - An in vitro study

被引:23
作者
Volodos, SM
Sayers, RD
Gostelow, JP
Bell, P
机构
[1] Univ Leicester, Dept Surg, Leicester LE1 7RH, Leics, England
[2] Univ Leicester, Dept Engn, Leicester LE1 7RH, Leics, England
[3] Kharkov Ctr Cardiovasc Surg, Kharkov, Ukraine
关键词
aortic aneurysm; stent graft migration; displacement force; hypertension;
D O I
10.1016/j.ejvs.2003.08.002
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives. To investigate the distraction forces affecting grafts used to treat abdominal aortic aneurysms in an in vitro model. Method. Using a standard cardiac pump and a rigid plastic circulation system, distraction forces were measured with a gramometer attached to a PTFE graft while the pressure inside a rigid aortic sac was varied. Results. If the pressure in the 'aneurysm sac' is maintained at the same level as the systemic pressure, the displacement force is zero. The displacement force is affected adversely by the level of systemic pressure, as this rises the displacement forces rise in an almost linear fashion. Conclusions. These observations may have important consequences for stent graft design and use in vivo pressurisation of a sealed sac may therefore not necessarily be an adverse event. Systemic hypertension is obviously important and its control may be necessary to prevent graft migration.
引用
收藏
页码:596 / 601
页数:6
相关论文
共 28 条
[1]   Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms [J].
Albertini, JN ;
Kalliafas, S ;
Travis, S ;
Yusuf, SW ;
Macierewicz, JA ;
Whitaker, SC ;
Elmarasy, NM ;
Hopkinson, BR .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 19 (03) :308-312
[2]   Lessons learned from the long-term follow-up of a first-generation aortic stent graft [J].
Alric, P ;
Hinchliffe, RJ ;
Wenham, PW ;
Whitaker, SC ;
Chuter, TAM ;
Hopkinson, BR .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (02) :367-373
[3]  
Chuter TA, 1993, J VASC SURG, V18, P195
[4]   TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
FIORE, WM ;
DEWEESE, JA ;
QUERAL, LA ;
CRIADO ;
NATH, RL ;
BERKOWITZ, HD ;
SUMPIO, BE .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) :185-197
[5]   Caudal migration of endoprostheses after treatment of abdominal aortic aneurysms [J].
Ebaugh, JL ;
Eskandari, MK ;
Finkelstein, A ;
Matsumura, JS ;
Morasch, MD ;
Hoff, FL ;
Pearce, WH .
JOURNAL OF SURGICAL RESEARCH, 2002, 107 (01) :14-17
[6]   Endovascular repair of infrarenal aortic aneurysms. Report on 4291 patients of the Eurostar database [J].
Enzler, MA ;
van Marrewijk, CJ ;
Buth, J ;
Harris, PL .
VASA-JOURNAL OF VASCULAR DISEASES, 2002, 31 (03) :167-172
[7]   Endovascular stent grafting in the presence of aortic neck filling defects: Early clinical experience [J].
Gitlitz, DB ;
Ramaswami, G ;
Kaplan, D ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) :340-344
[8]  
Hinchliffe RJ, 2002, J ROY COLL SURG EDIN, V47, P523
[9]  
Kalliafas S, 2002, J ENDOVASC THER, V9, P743, DOI 10.1583/1545-1550(2002)009<0743:SGMAER>2.0.CO
[10]  
2