Resistivity calculations in arterially perfused rabbit ventricles using a 4-electrode method

被引:1
作者
Baynham, TC [1 ]
Knisley, SB [1 ]
机构
[1] Univ Alabama, Dept Biomed Engn, Cardiac Rhythm Management Lab, Birmingham, AL 35294 USA
来源
PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING | 1997年 / 19卷
关键词
D O I
10.1109/IEMBS.1997.754502
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Resistivities were calculated from extracellular measurements on the left ventricular epicardium of isolated, arterially perfused rabbit hearts. A 4-electrode technique was used. The electrode configuration used consisted of four silver point electrodes in a line spaced 0.9 mm apart. A subthreshold current pulse was applied through the outer electrodes and the potential difference was measured through the inner electrodes. The analytical solution for calculation of resistivities derived by Plonsey and Barr was used to calculate the resistivities in the longitudinal and transverse fiber directions. The resistivities calculated were within the range of those found in other investigations. The ratio of transverse to longitudinal resistivity was found to be approximately 2:1.