Gas chromatography coupled with atomic absorption spectrometry - A sensitive instrumentation for mercury speciation

被引:43
作者
Emteborg, H
Sinemus, HW
Radziuk, B
Baxter, DC
Frech, W
机构
[1] UMEA UNIV,DEPT ANALYT CHEM,S-90187 UMEA,SWEDEN
[2] ZV BODENSEEWASSERVERSORGUNG BETRIEBS & FORSCHUNGS,D-78354 SIPPLINGEN,GERMANY
[3] BODENSEEWERK PERKIN ELMER & CO GMBH,D-88662 UBERLINGEN,GERMANY
关键词
capillary gas chromatography coupled with atomic absorption spectrometry; dithiocarbamate resin; methylmercury and inorganic mercury; speciation of mercury in natural waters;
D O I
10.1016/0584-8547(96)01482-6
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
New instrumentation for the speciation of mercury is described, and is applied to the analysis of natural water samples. The separation of mercury species is effected using gas chromatography of derivatized mercury species on a widebore capillary column. The solvent is vented using a bypass valve and the separated mercury species are pyrolysed on-line at 800 degrees C for production of mercury atoms. These are then detected by atomic absorption spectrometry (AAS) at the 253.7 and 184.9 nm lines simultaneously in a quartz cuvette. The use of the 184.9 nm line provides a more than five-fold increase in sensitivity compared with the conventional 253.7 nm line and an absolute detection limit of 0.5 pg of mercury. The dynamic range of the combined analytical lines provides a linear response over more than three orders of magnitude. A number of organic compounds not containing mercury are also detected following pyrolysis, especially at the 184.9 nm line. These background species must not co-elute at the retention times for methyl- and inorganic mercury, as otherwise a positive interference would result. By maximizing the chromatographic resolution and minimizing the band broadening in the cuvette by use of a make-up gas, the retention times of interest are freed from co-eluting background peaks. The instrumentation has been applied to the determination of ng 1(-1) concentrations of methyl- and inorganic mercury in Lake Constance, Germany and within the Lake Constance drinking water supply organization, Bodenseewasserversorgung (BWV). The accuracy for the sum of methyl- and inorganic mercury has been assessed by comparison with an independent method for total mercury based on AAS detection implemented at BWV. Relative detection limits using 1 litre water samples and 15 mi injections of the final hexane extract were 0.03 ng 1(-1) for methylmercury and 0.4 ng 1(-1) for inorganic mercury based on the 3j criterion.
引用
收藏
页码:829 / 837
页数:9
相关论文
共 21 条
[11]   MERCURY DETERMINATION BY FLAMELESS ATOMIC-ABSORPTION SPECTROSCOPY ON RESONANCE LINE 184.9 NM [J].
HOFFMAN, E ;
LUDKE, C ;
TILCH, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1979, 34 (7-8) :301-305
[12]   COMPARISON OF DISTILLATION WITH OTHER CURRENT ISOLATION METHODS FOR THE DETERMINATION OF METHYL MERCURY-COMPOUNDS IN LOW-LEVEL ENVIRONMENTAL-SAMPLES .2. WATER [J].
HORVAT, M ;
LIANG, L ;
BLOOM, NS .
ANALYTICA CHIMICA ACTA, 1993, 282 (01) :153-168
[13]  
KOLB B, 1966, Z ANAL CHEM, V21, P166
[14]   DETERMINATION OF METHYLMERCURY IN NATURAL-WATERS BY HEADSPACE GAS-CHROMATOGRAPHY WITH MICROWAVE-INDUCED PLASMA DETECTION AFTER PRECONCENTRATION ON A RESIN CONTAINING DITHIOCARBAMATE GROUPS [J].
LANSENS, P ;
MEULEMAN, C ;
LEERMAKERS, M ;
BAEYENS, W .
ANALYTICA CHIMICA ACTA, 1990, 234 (02) :417-424
[15]   DETERMINATION OF METHYLMERCURY IN NATURAL-WATERS AT THE SUB-NANOGRAMS PER LITER LEVEL BY CAPILLARY GAS-CHROMATOGRAPHY AFTER ADSORBENT PRECONCENTRATION [J].
LEE, YH ;
MOWRER, J .
ANALYTICA CHIMICA ACTA, 1989, 221 (02) :259-268
[16]   ATOMIC FLUORESCENCE SPECTROMETRY OF MERCURY - PRINCIPLES AND DEVELOPMENTS [J].
MORITA, H ;
TANAKA, H ;
SHIMOMURA, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (01) :69-84
[17]   FLAMELESS ATOMIC FLUORESCENCE SPECTROMETRY OF MERCURY BY DISPERSIVE AND NONDISPERSIVE SYSTEMS IN COMBINATION WITH COLD-VAPOR TECHNIQUE [J].
NAKAHARA, T ;
TANAKA, T ;
MUSHA, S .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1978, 51 (07) :2020-2024
[18]   EVALUATION OF A MICROWAVE CAVITY, DISCHARGE-TUBE, AND GAS-FLOW SYSTEM FOR COMBINED GAS-CHROMATOGRAPHY ATOMIC EMISSION DETECTION [J].
QUIMBY, BD ;
SULLIVAN, JJ .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1027-1034
[19]   ONLINE SPECIATION OF MERCURY AND METHYLMERCURY IN AQUEOUS SAMPLES BY CHROMATOGRAPHY ATOMIC FLUORESCENCE SPECTROMETRY AFTER HYDRIDE GENERATION [J].
RITSEMA, R ;
DONARD, OFX .
APPLIED ORGANOMETALLIC CHEMISTRY, 1994, 8 (7-8) :571-575
[20]  
SINEMUS HW, 1993, SPECTROCHIM ACTA B, V48, P1719