Polyaniline based nucleic acid sensor

被引:62
作者
Prabhakar, Nirmal [1 ,2 ]
Arora, Kavita [1 ]
Singh, Harpal [2 ]
Malhotra, Bansi D. [1 ]
机构
[1] Natl Phys Lab, Biomol Elect & Conducting Polymer Res Grp, New Delhi 110012, India
[2] Indian Inst Technol, Ctr Biomed Engn, New Delhi 110016, India
关键词
D O I
10.1021/jp711853q
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Twenty-bases long NH2-modified DNA and PNA probes specific to a pathogen (Mycobacterium tuberculosis) were covalently immobilized onto a polyaniline (PANI)/Au electrode to detect nucleic acid hybridization with complementary, one-base mismatch and noncomplementary targets within 30 s using Methylene Blue. The PNA-PANI/Au electrode exhibits improved specificity (1000 times) and detection limit (0.125 x 10(-18) M) as compared to that of the DNA-PANI/Au electrode (2.5 x 10(-18) M). These PNA-PANI/Au electrodes can be utilized for detection of hybridization with the complementary sequence in 5 min sonicated M. tuberculosis genomic DNA within I min of hybridization time. These DNA-PANI/Au and PNA-PANI/Au electrodes can be used 6-7 and 13-15 times, respectively.
引用
收藏
页码:4808 / 4816
页数:9
相关论文
共 50 条
[1]   Diagnostic approaches in patients with tuberculous pleural effusion [J].
Anie, Y. ;
Sumi, S. ;
Varghese, Philip ;
Madhavi, Latha G. K. ;
Sathish, Mundayoor ;
Radhakrishnan, V. V. .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2007, 59 (04) :389-394
[2]  
[Anonymous], 1999, SPECTROSCOPY POLYM
[3]   Escherichia coli genonsensor based on polyaniline (vol 79, pg 6152, 2007) [J].
Arora, Kavita ;
Prabhakar, Nirmal ;
Chand, Subhash ;
Malhotra, B. .
ANALYTICAL CHEMISTRY, 2008, 80 (05) :1833-1833
[4]   Ultrasensitive DNA hybridization biosensor based on polyaniline [J].
Arora, Kavita ;
Prabhakar, Nirmal ;
Chand, Subhash ;
Malhotra, B. D. .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (05) :613-620
[5]   Immobilization of single stranded DNA probe onto polypyrrole-polyvinyl sulfonate for application to DNA hybridization biosensor [J].
Arora, Kavita ;
Prabhakar, Nirmal ;
Chand, Subhash ;
Malhotra, B. D. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 126 (02) :655-663
[6]   Escherichia coli genosensor based on polyaniline [J].
Arora, Kavita ;
Prabhakar, Nirmal ;
Chand, Subhash ;
Malhotra, B. D. .
ANALYTICAL CHEMISTRY, 2007, 79 (16) :6152-6158
[7]   Electrochemical DNA biosensor based on conducting polyaniline nanotube array [J].
Chang, Haixin ;
Yuan, Ying ;
Shi, Nanlin ;
Guan, Yifu .
ANALYTICAL CHEMISTRY, 2007, 79 (13) :5111-5115
[8]  
Chauhan A, 2004, Indian J Med Microbiol, V22, P238
[9]   A new multi-PCR-SSCP assay for simultaneous detection of isoniazid and rifampin resistance in Mycobacterium tuberculosis [J].
Cheng, Xiaodong ;
Zhang, Jianfang ;
Yang, Liu ;
Xu, Xiuli ;
Liu, Jianyun ;
Yu, Wenbin ;
Su, Mingquan ;
Hao, Xiaoke .
JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 70 (02) :301-305
[10]   Tuberculosis: Diagnostics [J].
Cho, Sang-Nae ;
Brennan, Patrick J. .
TUBERCULOSIS, 2007, 87 :S14-S17