Pancreatic malignancy: Value of arterial, pancreatic, and hepatic phase imaging with multi-detector row CT

被引:188
作者
Fletcher, JG
Wiersema, MJ
Farrell, MA
Fidler, JL
Burgart, LJ
Koyama, T
Johnson, CD
Stephens, DH
Ward, EM
Harmsen, WS
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Div Gastroenterol & Hepatol, Dept Internal Med & Pathol, Rochester, MN 55905 USA
[3] Mayo Clin, Div Biostat, Rochester, MN 55905 USA
关键词
computed tomography (CT); multi-detection row; phase imaging; pancreas; neoplasms;
D O I
10.1148/radiol.2291020582
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the value of arterial, pancreatic, and hepatic phase imaging at multi-detector row computed tomography (CT) of the pancreas for pancreatic malignancy. MATERIALS AND METHODS: Thirty-nine patients suspected of having resectable pancreatic adenocarcinoma underwent triple-phase multi-detector row CT. Images obtained during each phase were interpreted by one radiologist who evaluated presence of tumor, vascular invasion, and flow artifacts in the superior mesenteric vein and measured attenuation of tumor, normal pancreas, aorta, and superior mesenteric vein. Results were compared with histologic, follow-up, and correlative imaging findings. RESULTS: Mean tumor-to-gland attenuation difference was greatest on images obtained in the pancreatic phase (42 HU) versus that on those obtained in the hepatic phase (35 HU) and in the arterial phase (25 HU). For tumor detection, sensitivity of the images obtained in pancreatic (0.97 [29 of 30]) and hepatic (0.93 [28 of 30]) phases was superior to that of those obtained in arterial phase (0.63 [19 of 30]) (P less than or equal to .008). For vascular invasion detection, sensitivity of images obtained in the hepatic phase (0.83) was better than that of those obtained in the pancreatic (0.58) and arterial (0.25) phases. Images obtained in the pancreatic phase demonstrated more flow artifacts and decreased attenuation in the superior mesenteric vein, compared with the artifacts revealed on images obtained in the hepatic phase. CONCLUSION: Routine acquisition of images in the arterial phase is unnecessary for detection of pancreatic adenocarcinoma. Images of the pancreas obtained in the hepatic phase with multi-detector row CT most accurately display vascular invasion. (C) RSNA, 2003.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 18 条
  • [1] UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER
    BARON, RL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) : 323 - 331
  • [2] Pancreatic-phase versus portal vein-phase helical CT of the pancreas: Optimal temporal window for evaluation of pancreatic adenocarcinoma
    Boland, GW
    O'Malley, ME
    Saez, M
    Fernandez-del-Castillo, C
    Warshaw, AL
    Mueller, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) : 605 - 608
  • [3] CHARNSANGAVEJ C, 2000, SOC GASTR RAD POSTGR
  • [4] Arterial versus portal venous helical CT for revealing pancreatic adenocarcinoma: Conspicuity of tumor and critical vascular anatomy
    Graf, O
    Boland, GW
    Warshaw, AL
    FernandezdelCastillo, C
    Hahn, PF
    Mueller, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) : 119 - 123
  • [5] QUANTITATIVE-EVALUATION OF PANCREATIC ENHANCEMENT DURING DUAL-PHASE HELICAL CT
    HOLLETT, MD
    JORGENSEN, MJ
    JEFFREY, RB
    [J]. RADIOLOGY, 1995, 195 (02) : 359 - 361
  • [6] Teardrop superior mesenteric vein: CT sign for unresectable carcinoma of the pancreas
    Hough, TJ
    Raptopoulos, V
    Siewert, B
    Matthews, JB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (06) : 1509 - 1512
  • [7] Assessing the resectability of pancreatic carcinoma: The value of reinterpreting abdominal CT performed at other institutions
    Kalbhen, CL
    Yetter, EM
    Olson, MC
    Posniak, HV
    Aranha, GV
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (06) : 1571 - 1576
  • [8] Pancreatic malignancy: Effect of dual-phase helical CT in tumor detection and vascular opacification
    Keogan, MT
    McDermott, VG
    Paulson, EK
    Sheafor, DH
    Frederick, MG
    DeLong, DM
    Nelson, RC
    [J]. RADIOLOGY, 1997, 205 (02) : 513 - 518
  • [9] Pancreatic CT imaging: Effects of different injection rates and doses of contrast material
    Kim, T
    Murakami, T
    Takahashi, S
    Okada, A
    Hori, M
    Narumi, Y
    Nakamura, H
    [J]. RADIOLOGY, 1999, 212 (01) : 219 - 225
  • [10] Effects of injection rates of contrast material on arterial phase hepatic CT
    Kim, T
    Murakami, T
    Takahashi, S
    Tsuda, K
    Tomoda, K
    Narumi, Y
    Oi, H
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 429 - 432