Needle-type lactate biosensor

被引:67
作者
Yang, QL [1 ]
Atanasov, P [1 ]
Wilkins, E [1 ]
机构
[1] Univ New Mexico, Dept Chem & Nucl Engn, Albuquerque, NM 87131 USA
关键词
needle-type sensor; amperometric transducer; lactate oxidase; dithiothreitol; stabilizer;
D O I
10.1016/S0956-5663(98)00109-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A needle-type lactate biosensor has been developed for continuous intravascular lactate monitoring. The sensor employs poly(1,3-phenylenediamine) as the inner layer on the platinum electrode in order to eliminate the interference from oxidizable physiological substances. Cross-linking with glutaraldehyde was used for enzyme immobilization. Dithiothreitol was used as the stabilizer of lactate oxidase. PVC (polyvinyl chloride) was chosen as the external diffusion control membrane. Sensor performance was evaluated in vitro and the sensor shows a sensitivity of 10-15 nA/mM, and a linear range from 1 mM to at least 15 mM lactate. Evaluation of the sensor response in blood plasma showed similar sensitivity and linear range as indicated by the calibration curves obtained in buffer solution. The sensor has a short response time of approximately 1 minute. The sensors were operated continuously for 7 days in phosphate buffer containing solution with a concentration at the physiological lactate level. No significant change in sensor sensitivity and its linear range has been observed. Sensors show a minimum change in its performance when stored in buffer at 4 degrees C for at least 9 months. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 35 条
[1]   AMPEROMETRIC BIOSENSOR BASED ON CARBON-PASTE MIXED WITH ENZYME, LIPID AND CYTOCHROME-C [J].
AMINE, A ;
DENI, J ;
KAUFFMANN, JM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1994, 34 (02) :123-128
[2]   A CONTINUOUS, IMPLANTABLE LACTATE SENSOR [J].
BAKER, DA ;
GOUGH, DA .
ANALYTICAL CHEMISTRY, 1995, 67 (09) :1536-1540
[3]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .6. MICROELECTRODES FOR THE DETECTION OF L-LACTATE BASED ON FLAVOCYTOCHROME B(2) IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1994, 119 (02) :175-180
[4]   DITHIOTHREITOL NEW PROTECTIVE REAGENT FOR SH GROUPS [J].
CLELAND, WW .
BIOCHEMISTRY, 1964, 3 (04) :480-&
[5]  
Collier WA, 1997, AUSTRALAS BIOTECHNOL, V7, P93
[6]   THE RELATIVE PROGNOSTIC VALUE OF LACTATE AND HEMODYNAMIC MEASUREMENTS IN EARLY SHOCK [J].
COWAN, BN ;
BURNS, HJG ;
BOYLE, P ;
LEDINGHAM, IM .
ANAESTHESIA, 1984, 39 (08) :750-755
[7]   ELECTROPOLYMERIZED O-PHENYLENEDIAMINE FILM AS MEANS OF IMMOBILISING LACTATE OXIDASE FOR A L-LACTATE BIOSENSOR [J].
DEMPSEY, E ;
WANG, J ;
SMYTH, MR .
TALANTA, 1993, 40 (03) :445-451
[8]   AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF LACTATE IN SWEAT [J].
FARIDNIA, MH ;
PALLESCHI, G ;
LUBRANO, GJ ;
GUILBAULT, GG .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :35-40
[9]   IMMOBILIZATION OF LACTATE OXIDASE IN A POLY(VINYL ALCOHOL) MATRIX ON PLATINIZED GRAPHITE-ELECTRODES BY CHEMICAL CROSS-LINKING WITH ISOCYANATE [J].
HAJIZADEH, K ;
HALSALL, HB ;
HEINEMAN, WR .
TALANTA, 1991, 38 (01) :37-47
[10]   Stabilization of lactate oxidase in screen-printed enzyme electrodes [J].
Hart, AL ;
Cox, H ;
Janssen, D .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (08) :833-837