Collection of selected reaction monitoring and full scan data on a time scale suitable for target compound quantitative analysis by liquid chromatography/tandem mass spectrometry

被引:24
作者
King, RC [1 ]
Gundersdorf, R [1 ]
Fernández-Metzler, CL [1 ]
机构
[1] Merck & Co Inc, Dept Drug Metab, W Point, PA 19486 USA
关键词
D O I
10.1002/rcm.1214
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A hybrid linear ion trap/triple quadrupole mass spectrometer was used to demonstrate the value of collecting full scan qualitative data during quantitative analysis of target compounds. We present examples of the additional information that can be obtained from plasma samples analyzed primarily for target compound concentrations. This information includes detection of circulating metabolites, dosing vehicle, interfering matrix components, and potential interfering drug conjugates. Additionally, the quantitative results from selected reaction monitoring (SRM) analysis and from combined full scan and SRM analysis (SRM/EMS) were compared. The quantitative data in both scan modes are acceptable in terms of sensitivity, accuracy and precision. One can conclude from this work that the hybrid linear ion trap/triple quadrupole mass analyzer can provide in a single analysis both useful qualitative data, and accurate and precise quantitative data from the samples routinely prepared and analyzed for target drug concentrations. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:2413 / 2422
页数:10
相关论文
共 20 条
[1]  
[Anonymous], [No title captured]
[2]  
Cai ZW, 2000, RAPID COMMUN MASS SP, V14, P1637, DOI 10.1002/1097-0231(20000930)14:18<1637::AID-RCM73>3.0.CO
[3]  
2-2
[4]   High-throughput analysis in drug discovery:: application of liquid chromatography/ion-trap mass spectrometry for simultaneous cassette analysis of α-1a antagonists and their metabolites in mouse plasma [J].
Cai, ZW ;
Han, C ;
Harrelson, S ;
Fung, E ;
Sinhababu, AK .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (08) :546-550
[5]  
Decaestecker TN, 2000, RAPID COMMUN MASS SP, V14, P1787, DOI 10.1002/1097-0231(20001015)14:19<1787::AID-RCM94>3.0.CO
[6]  
2-S
[7]  
Gilbert JD, 1996, ACS SYM SER, V619, P330
[8]   Product ion scanning using a Q-q-Qlinear ion trap (Q TRAP™) mass spectrometer [J].
Hager, JW ;
Le Blanc, JCY .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (10) :1056-1064
[9]   A new linear ion trap mass spectrometer [J].
Hager, JW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) :512-526
[10]   Transformations in pharmaceutical research and development, driven by innovations in multidimensional mass spectrometry-based technologies [J].
Hoke, SH ;
Morand, KL ;
Greis, KD ;
Baker, TR ;
Harbol, KL ;
Dobson, RLM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 212 (1-3) :135-196