Product ion scanning using a Q-q-Qlinear ion trap (Q TRAP™) mass spectrometer

被引:115
作者
Hager, JW [1 ]
Le Blanc, JCY [1 ]
机构
[1] MDS SCIEX, Concord, ON L4K 4V8, Canada
关键词
D O I
10.1002/rcm.1020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of a Q-q-Q(linear) (ion trap) instrument to obtain product ion spectra is described. The instrument is based on the ion path of a triple quadrupole mass spectrometer with Q3 operable as either a conventional RF/DC quadrupole mass filter or a linear ion trap mass spectrometer with axial ion ejection. This unique ion optical arrangement allows de-coupling of precursor ion isolation and fragmentation from the ion trap itself. The result is a high sensitivity tandem mass spectrometer with triple quadrupole fragmentation patterns and no inherent low mass cut-off. The use of the entrance RF-only section of the instrument as accumulation ion trap while the linear ion trap mass spectrometer is scanning enhances duty cycles and results in increased sensitivities by as much as a factor of 20. The instrument is also capable of all of the triple quadrupole scans including multiple-reaction monitoring (MRM) as well as precursor and constant neutral loss scanning. The high product ion scanning sensitivity allows the recording of useful product ion spectra near the MRM limit of quantitation. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:1056 / 1064
页数:9
相关论文
共 23 条
  • [1] Beaudry F, 1998, RAPID COMMUN MASS SP, V12, P1216, DOI 10.1002/(SICI)1097-0231(19980915)12:17<1216::AID-RCM304>3.0.CO
  • [2] 2-O
  • [3] Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization
    Belov, ME
    Anderson, GA
    Angell, NH
    Shen, YF
    Tolic, N
    Udseth, HR
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5052 - 5060
  • [4] A new technique for unbiased external ion accumulation in a quadrupole two-dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Belov, ME
    Nikolaev, EN
    Alving, K
    Smith, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) : 1172 - 1180
  • [5] Optimal pressure conditions for unbiased external ion accumulation in a two-dimensional radio-frequency quadrupole for Fourier transform ion cyclotron resonance mass spectrometry
    Belov, ME
    Gorshkov, MV
    Alving, K
    Smith, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (21) : 1988 - 1996
  • [6] Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer
    Belov, ME
    Nikolaev, EN
    Harkewicz, R
    Masselon, CD
    Alving, K
    Smith, RD
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) : 205 - 225
  • [7] Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Udseth, HR
    Conrads, TP
    Veenstra, TD
    Masselon, CD
    Gorshkov, MV
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 253 - 261
  • [8] An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system
    Cha, BC
    Blades, M
    Douglas, DJ
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5647 - 5654
  • [9] Douglas DJ, 1993, US Patent, Patent No. [5179278, 5,179,278]
  • [10] A new linear ion trap mass spectrometer
    Hager, JW
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) : 512 - 526