Voltammetric oxidation of NADH at phenyl azo aniline/PEDOT modified electrode

被引:28
作者
Balamurugan, A. [1 ]
Chen, Shen-Ming [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Electroanal & Bioelectrochem Lab, Taipei 106, Taiwan
关键词
4-PAA; NADH; FIA; electrodeposition; electroanalysis;
D O I
10.1016/j.snb.2007.09.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly (3,4-ethylenedioxythiophene) (PEDOT) electrode, modified by the electrodeposition of 4-phenyl azo aniline (4-PAA) in which 4-PAA acts as mediator, was prepared by cyclic voltammetric procedure. Here after, the above modified electrode denoted as 4-PAA/PEDOT/GC modified electrode. The electrochemical properties and an effect of pH on the redox properties of 4-PAA/PEDOT/GC modified electrode were studied by cyclic voltammetrically and it was found that pH dependent electrode. The voltammogram shows that 4-PAA/PEDOT/GC modified electrode has surface confined character in KHP buffer solution. 4-PAA/PEDOT/GC electrode exhibits electrocatalytic, activity towards the oxidation of NADH (dihydronicotinamide adenine dinucleotide) with an activation overpotential, which is ca 400 mV lower than bare electrode. In the 4-PAA/PEDOT/GC modified electrode, the PEDOT film plays important role to separate oxidation peaks of NADH and ascorbic acid (AA). The modified electrode exhibits stable FIA amperometric response and the detection limit was 50 nM in physiological pH. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:850 / 858
页数:9
相关论文
共 62 条
[1]  
ALVAREZ ND, 2005, ANAL CHEM, V77, P2624
[2]  
Alvarez NDS, 2001, J ELECTROANAL CHEM, V502, P109
[3]   VOLTAMMETRIC STUDIES OF THE OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE AT A CONDUCTING POLYMER ELECTRODE [J].
ATTA, NF ;
GALAL, A ;
KARAGOZLER, AE ;
ZIMMER, H ;
RUBINSON, JF ;
MARK, HB .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1990, (19) :1347-1349
[4]   Exploring the electrocatalytic sites of carbon nanotubes for NADH detection: an edge plane pyrolytic graphite electrode study [J].
Banks, CE ;
Compton, RG .
ANALYST, 2005, 130 (09) :1232-1239
[5]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[6]   Modified electrodes for NADH oxidation and dehydrogenase-based biosensors [J].
Bartlett, PN ;
Simon, E ;
Toh, CS .
BIOELECTROCHEMISTRY, 2002, 56 (1-2) :117-122
[7]   Poly(aniline)-poly(acrylate) composite films as modified electrodes for the oxidation of NADH [J].
Bartlett, PN ;
Simon, E .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2000, 2 (11) :2599-2606
[8]   Measurement of the kinetic isotope effect for the oxidation of NADH at a poly(aniline)-modified electrode [J].
Bartlett, PN ;
Simon, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (14) :4014-4015
[9]   STUDY OF ELECTROCHEMICAL OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE [J].
BLAEDEL, WJ ;
JENKINS, RA .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1337-1343
[10]   Electrocatalysis of NADH oxidation with electropolymerized films of nile blue A [J].
Cai, CX ;
Xue, KH .
ANALYTICA CHIMICA ACTA, 1997, 343 (1-2) :69-77