Clinical applications of diffusion tensor imaging

被引:158
作者
Dong, Q [1 ]
Welsh, RC [1 ]
Chenevert, TL [1 ]
Carlos, RC [1 ]
Maly-Sundgren, P [1 ]
Gomez-Hassan, DM [1 ]
Mukherji, SK [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, MRI Div, Ann Arbor, MI 48109 USA
关键词
diffusion tensor; MRI; DTI; brain; apparent diffusion coefficient; diffusion anisotropy;
D O I
10.1002/jmri.10424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Directionally-ordered cellular structures that impede water motion, such as cell membranes and myelin, result in water mobility that is also directionally-dependent. Diffusion tensor imaging characterizes this directional nature of water motion and thereby provides structural information that cannot be obtained by standard anatomic imaging. Quantitative apparent diffusion coefficients and fractional anisotropy have emerged from being primarily research tools to methods enabling valuable clinical applications. This review describes the clinical utility of diffusion tensor imaging, including the basic principles of the technique, acquisition, data analysis, and the major clinical applications.
引用
收藏
页码:6 / 18
页数:13
相关论文
共 106 条
[1]   ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[2]   Diffusion tensor MRI in temporal lobe epilepsy [J].
Arfanakis, K ;
Hermann, B ;
Rogers, BP ;
Carew, JD ;
Seidenberg, M ;
Meyerand, ME .
MAGNETIC RESONANCE IMAGING, 2002, 20 (07) :511-519
[3]   CORTICAL EVOKED-POTENTIAL AND EXTRACELLULAR K+ AND H+ AT CRITICAL LEVELS OF BRAIN ISCHEMIA [J].
ASTRUP, J ;
SYMON, L ;
BRANSTON, NM ;
LASSEN, NA .
STROKE, 1977, 8 (01) :51-57
[4]   Diffusion tensor imaging using single-shot SENSE-EPI [J].
Bammer, R ;
Auer, M ;
Keeling, SL ;
Augustin, M ;
Stables, LA ;
Prokesch, RW ;
Stollberger, R ;
Moseley, ME ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :128-136
[5]  
Bammer R, 2000, MAGNET RESON MED, V44, P583, DOI 10.1002/1522-2594(200010)44:4<583::AID-MRM12>3.0.CO
[6]  
2-O
[7]  
Bammer R, 2002, P 10 ANN M ISMRM HON, P1111
[8]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[9]  
2-O
[10]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934