A Biomechanical Study of Posteromedial Tibial Plateau Fracture Stability: Do They All Require Fixation?

被引:33
作者
Cuellar, Vanessa G. [1 ]
Martinez, Danny [2 ]
Immerman, Igor [1 ]
Oh, Cheongeun [3 ]
Walker, Peter S. [2 ]
Egol, Kenneth A. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed Surg, New York, NY 10003 USA
[2] NYU, Hosp Joint Dis, Dept Orthopaed Surg, Lab Orthopaed Implant Design, New York, NY 10003 USA
[3] NYU, Sch Med, Dept Populat Hlth, Div Biostat, New York, NY 10003 USA
关键词
posteromedial tibial plateau fracture; fracture stability; trauma; LESS INVASIVE STABILIZATION; FRAGMENT; KNEE; MORPHOLOGY; LOCKING; JOINT;
D O I
10.1097/BOT.0000000000000277
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Objectives:Although the posteromedial fragment in tibial plateau fractures is often considered unstable, biomechanical evidence supporting this view is lacking. We aimed to evaluate the stability of the fragment in a cadaver model. Our hypothesis was that under the expected small axial force during rehabilitation and the combined effects of this force with shear force, internal rotation torque, and varus moment, the most common posteromedial tibial fragment morphology could maintain stability in early flexion.Methods:Axial compression force alone or combined with posterior shear, internal rotation torque, or varus moment was applied to the femurs of 5 fresh cadaveric knees. A Tekscan pressure mapping system was used to measure pressure and contact area between the femoral condyles, meniscus, and tibial plateau. A Microscribe 3D digitizer was used to define the 3-dimensional positions of the femur and tibia. A 10-mm and then a 20-mm osteotomy was created with a saw at an angle of 30 degrees in the axial plane with respect to the tangent of the posterior tibial plateau and 75 degrees in the sagittal plane, representing a typical posteromedial fracture fragment. At each flexion angle (15, 30, 60, 90, and 120 degrees) and loading condition (axial compression only, compression with shear force, torque, and varus moment), distal displacement of the medial femoral condyle and the tibial fracture fragments was determined.Results:For the 10-mm fragment, medial femoral condyle displacement was little affected up to approximately 30-degree flexion, after which it increased. For the 20-mm fragment, there was progressive medial femoral condyle displacement with increasing flexion from baseline. However, for the 10- and 20-mm fragments themselves, displacements were noted at every flexion angle, starting at 1.7 mm inferior displacement with 15 degrees of flexion and internal rotation torque and up to 10.2 mm displacement with 90 degrees of flexion and varus bending moment.Conclusions:In this cadaveric model of a posteromedial tibial plateau fracture, both fracture fragments studied displaced with knee flexion, even at low flexion angles. Although such fragments may initially seem nondisplaced after injury, posteromedial fragments similar to these tested are likely to displace during knee range of motion exercises in non-weight-bearing conditions.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 22 条
[1]
Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns [J].
Barei, David P. ;
O'Mara, Timothy J. ;
Taitsman, Lisa A. ;
Dunbar, Robert P. ;
Nork, Sean E. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (03) :176-182
[2]
In vivo tibiofemoral contact analysis using 3D MRI-based knee models [J].
DeFrate, LE ;
Sun, H ;
Gill, TJ ;
Rubash, HE ;
Li, GA .
JOURNAL OF BIOMECHANICS, 2004, 37 (10) :1499-1504
[3]
Unstable Bicondylar Tibial Plateau Fractures: A Clinical Investigation [J].
Eggli, Stefan ;
Hartel, Maximilian J. ;
Kohl, Sandro ;
Hallpt, Uli ;
Exadakrylos, Aristomenis K. ;
Roeder, Christoph .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (10) :673-679
[4]
The movement of the normal tibio-femoral joint [J].
Freeman, MAR ;
Pinskerova, V .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :197-208
[5]
Gösling T, 2004, J ORTHOP TRAUMA, V18, P546
[6]
ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months [J].
Heinlein, Bernd ;
Kutzner, Ines ;
Graichen, Friedmar ;
Bender, Alwina ;
Rohlmann, Antonius ;
Halder, Andreas M. ;
Beier, Alexander ;
Bergmann, Georg .
CLINICAL BIOMECHANICS, 2009, 24 (04) :315-326
[7]
Incidence and Morphology of the Posteromedial Fragment in Bicondylar Tibial Plateau Fractures [J].
Higgins, Thomas E. ;
Kemper, Dan ;
Klatt, Joshua .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (01) :45-51
[8]
Biomechanical analysis of bicondylar tibial plateau fixation: How does lateral locking plate fixation compare to dual plate fixation? [J].
Higgins, Thomas F. ;
Klatt, Joshua ;
Bachus, Kent N. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :301-306
[9]
Stability of the Posteromedial Fragment in a Tibial Plateau Fracture [J].
Immerman, Igor ;
Bechtel, Christopher ;
Yildirim, Gokce ;
Heller, Yonah ;
Walker, Peter S. ;
Egol, Kenneth A. .
JOURNAL OF KNEE SURGERY, 2013, 26 (02) :117-126
[10]
A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures [J].
Jiang, Rui ;
Luo, Cong-Feng ;
Wang, Ming-Chun ;
Yang, Tie-Yi ;
Zeng, Bing-Fang .
KNEE, 2008, 15 (02) :139-143