In vivo tibiofemoral contact analysis using 3D MRI-based knee models

被引:162
作者
DeFrate, LE
Sun, H
Gill, TJ
Rubash, HE
Li, GA
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Bioengn Lab, Boston, MA 02114 USA
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
in vivo knee kinematics; cartilage contact; soft tissue biomechanics; magnetic resonance imaging; imaging;
D O I
10.1016/j.jbiomech.2004.01.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper quantified the motion of the tibiofemoral contact points during in vivo weight bearing flexion using MRI-based 3D knee models and two orthogonal fluoroscopic images. The contact points on the medial and lateral tibial plateau were calculated by finding the centroid of the intersection of the tibial and femoral cartilage layers and by using the bony geometry alone. Our results indicate that the medial femoral condyle remains in the central portion of the tibial plateau and the lateral condyle translates posteriorly with increasing flexion. Using the bony contact model increased the total translation of the medial and lateral condyles by 250 and 55%, respectively, compared to the cartilage contact model. These results suggest that using the bony geometry alone may not accurately represent the articular surfaces of the knee. Articular cartilage geometry may have to be used to accurately quantify tibiofemoral contact. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1499 / 1504
页数:6
相关论文
共 32 条
[1]   In vivo three-dimensional knee kinematics using a biplanar image-matching technique [J].
Asano, T ;
Akagi, M ;
Tanaka, K ;
Tamura, J ;
Nakamura, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) :157-166
[2]   A STEREOPHOTOGRAMMETRIC METHOD FOR DETERMINING IN-SITU CONTACT AREAS IN DIARTHROIDAL JOINTS, AND A COMPARISON WITH OTHER METHODS [J].
ATESHIAN, GA ;
KWAK, SD ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :111-124
[3]   QUANTITATION OF ARTICULAR SURFACE-TOPOGRAPHY AND CARTILAGE THICKNESS IN KNEE JOINTS USING STEREOPHOTOGRAMMETRY [J].
ATESHIAN, GA ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1991, 24 (08) :761-776
[4]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]   Quantification of patellofemoral joint contact area using magnetic resonance imaging [J].
Brechter, JH ;
Powers, CM ;
Terk, MR ;
Ward, SR ;
Lee, TQ .
MAGNETIC RESONANCE IMAGING, 2003, 21 (09) :955-959
[6]   LIGAMENTOUS RESTRAINTS TO ANTERIOR-POSTERIOR DRAWER IN THE HUMAN KNEE - BIOMECHANICAL STUDY [J].
BUTLER, DL ;
NOYES, FR ;
GROOD, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (02) :259-270
[7]   Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements [J].
Cohen, ZA ;
McCarthy, DM ;
Kwak, SD ;
Legrand, P ;
Fogarasi, F ;
Ciaccio, EJ ;
Ateshian, GA .
OSTEOARTHRITIS AND CARTILAGE, 1999, 7 (01) :95-109
[8]   In vivo morphometry and functional analysis of human articular cartilage with quantitative magnetic resonance imaging - from image to data, from data to theory [J].
Eckstein, F ;
Reiser, M ;
Englmeier, KH ;
Putz, R .
ANATOMY AND EMBRYOLOGY, 2001, 203 (03) :147-173
[9]   Gender differences in lower extremity mechanics during running [J].
Ferber, R ;
Davis, IM ;
Williams, DS .
CLINICAL BIOMECHANICS, 2003, 18 (04) :350-357
[10]   AN INVITRO BIOMECHANICAL EVALUATION OF ANTERIOR-POSTERIOR MOTION OF THE KNEE - TIBIAL DISPLACEMENT, ROTATION, AND TORQUE [J].
FUKUBAYASHI, T ;
TORZILLI, PA ;
SHERMAN, MF ;
WARREN, RF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) :258-264