Measurement of midfemoral shaft geometry: Repeatability and accuracy using magnetic resonance imaging and dual-energy X-ray absorptiometry

被引:36
作者
Woodhead, HJ [1 ]
Kemp, AF
Blimkie, CJR
Briody, JN
Duncan, CS
Thompson, M
Lam, A
Howman-Giles, R
Cowell, CT
机构
[1] Childrens Hosp Westmead, Robert Vines Growth Res Ctr, Sydney, NSW 2145, Australia
[2] Univ Sydney, Dept Paediat & Child Hlth, Sydney, NSW 2006, Australia
[3] Childrens Hosp Westmead, Dept Radiol, Sydney, NSW 2145, Australia
[4] Australian Catholic Univ, Dept Exercise Sci, Sydney, NSW, Australia
[5] McMaster Univ, Dept Kinesiol, Hamilton, ON, Canada
[6] Childrens Hosp Westmead, Dept Nucl Med, Sydney, NSW 2145, Australia
关键词
midfemoral shaft; bone geometry; magnetic resonance imaging; dual-energy X-ray absorptiometry; cortical bone volume;
D O I
10.1359/jbmr.2001.16.12.2251
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although macroscopic geometric architecture is an important determinant of bone strength, there is limited published information relating to the validation of the techniques used in its measurement. This study describes new techniques for assessing geometry at the midfemur using magnetic resonance imaging (MRI) and dual-energy X-ray absorptiometry (DXA) and examines both the repeatability and the accuracy of these and previously described DXA methods. Contiguous transverse MRI (Philips 1.5T) scans of the middle one-third femur were made in 13 subjects, 3 subjects with osteoporosis. Midpoint values for total width (TW), cortical width (CW), total cross-sectional area (TCSA), cortical cross-sectional area (CCSA), and volumes from reconstructed three-dimensional (3D) images (total volume [TV] and cortical volume [CVol]) were derived. Midpoint TW and CW also were determined using DXA (Lunar V3.6, lumbar software) by visual and automated edge detection analysis. Repeatability was assessed on scans made on two occasions and then analyzed twice by two independent observers (blinded), with intra- and interobserver repeatability expressed as the CV (CV +/- SD). Accuracy was examined by comparing MRI and DXA measurements of venison bone (and Perspex phantom for MRI), against "gold standard" measures made by vernier caliper (width), photographic image digitization (area) and water displacement (volume). Agreement between methods was analyzed using mean differences (MD +/- SD %). MRI CVs ranged from 0.5 +/- 0.5 % (TV) to 3.1 +/- 3.1 % (CW) for intraobserver and 0.55 +/- 0.5 % (TV) to 3.6 +/- 3.6 % (CW) for interobserver repeatability. DXA results ranged from 1.6 +/- 1.5 % (TW) to 4.4 : 4.5 % (CW) for intraobserver and 3.8 +/- 3.8% (TW) to 8.3 +/- 8.1% (CW) for interobserver variation. MRI accuracy was excellent for TV (3.3 +/- 6.4%), CVoI (3.5 +/- 4.0%), TCSA (1.8 +/- 2.6%), and CCSA (1.6 +/- 4.2%) but not TW (4.1 +/- 1.4%) or CW (16.4 +/- 14.9 %). DXA results were TW (6.8 +/- 2.7 %) and CW (16.4 +/- 17.0 %). MRI measures of geometric parameters of the midfemur are highly accurate and repeatable, even in osteoporosis. Both MRI and DXA techniques have limited value in determining cortical width. MRI may prove valuable in the assessment of surface-specific bone accrual and resorption responses to disease, therapy, and variations in mechanical loading.
引用
收藏
页码:2251 / 2259
页数:9
相关论文
共 38 条
[21]   BRIEF COMMUNICATION - NONCIRCULAR GEOMETRY AND RADIOGRAMMETRY OF THE 2ND METACARPAL [J].
LAZENBY, R .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1995, 97 (03) :323-327
[22]  
Martin R, 1998, SKELETAL TISSUE MECH, P138
[23]   NON-INVASIVE MEASUREMENT OF LONG-BONE CROSS-SECTIONAL MOMENT OF INERTIA BY PHOTON-ABSORPTIOMETRY [J].
MARTIN, RB ;
BURR, DB .
JOURNAL OF BIOMECHANICS, 1984, 17 (03) :195-201
[24]  
Mazess R. B., 1988, OSTEOPOROSIS ETIOLOG, P251
[25]  
MELTON LJ, 1993, J BONE MINER RES, V8, P1227
[26]   CORRELATIONS BETWEEN PHOTON-ABSORPTION PROPERTIES AND FAILURE LOAD OF THE DISTAL RADIUS INVITRO [J].
MYERS, ER ;
SEBENY, EA ;
HECKER, AT ;
CORCORAN, TA ;
HIPP, JA ;
GREENSPAN, SL ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (04) :292-297
[27]   GEOMETRIC VARIABLES FROM DXA OF THE RADIUS PREDICT FOREARM FRACTURE LOAD INVITRO [J].
MYERS, ER ;
HECKER, AT ;
ROOKS, DS ;
HIPP, JA ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (03) :199-204
[28]  
OTT SM, 1987, J BONE MINER RES, V2, P201
[29]   Age at menarche and cortical bone geometry in premenopausal women [J].
Rauch, F ;
Klein, K ;
Allolio, B ;
Schönau, E .
BONE, 1999, 25 (01) :69-73
[30]   Vitamin D-receptor gene polymorphisms and bone density in prepubertal American girls of Mexican descent [J].
Sainz, J ;
VanTornout, JM ;
Loro, ML ;
Sayre, J ;
Roe, TF ;
Gilsanz, V .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (02) :77-82