Coherence experiments at the energy-dispersive reflectometry beamline at BESSY II

被引:9
作者
Panzner, T [1 ]
Leitenberger, W
Grenzer, J
Bodenthin, Y
Geue, T
Pietsch, U
Möhwald, H
机构
[1] Univ Potsdam, Inst Phys, D-14415 Potsdam, Germany
[2] MPI Kolloid & Grenzflachenforsch, D-14476 Golm, Germany
关键词
D O I
10.1088/0022-3727/36/10A/319
中图分类号
O59 [应用物理学];
学科分类号
摘要
Fraunhofer patterns of a 5 mum entrance pinhole were detected at the white-beam bending-magnet beamline at BESSY II. Using an energy-dispersive detector the Fraunhofer fringes could be recorded simultaneously between 5 < E < 15 keV. At the present apparative conditions the intensity is sufficient to resolve Fraunhofer fringes of more than five orders. After the successful investigation of the Fraunhofer diffraction over a large energy band pass static speckle pattern were measured from the optical components of the set-up. The proposed technique seems to be suitable for a fast characterization of coherent properties over a wide energy range.
引用
收藏
页码:A93 / A97
页数:5
相关论文
共 9 条
[1]   Small-angle X-ray scattering using coherent undulator radiation at the ESRF [J].
Abernathy, DL ;
Grubel, G ;
Brauer, S ;
McNulty, I ;
Stephenson, GA ;
Mochrie, SGJ ;
Sandy, AR ;
Mulders, N ;
Sutton, M .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :37-47
[2]   Phase objects in synchrotron radiation hard x-ray imaging [J].
Cloetens, P ;
Barrett, R ;
Baruchel, J ;
Guigay, JP ;
Schlenker, M .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (01) :133-146
[3]   Source size and emittance monitoring on BESSY II [J].
Holldack, K ;
Feikes, J ;
Peatman, WB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :235-238
[4]   Coherent small-angle scattering on a bending-magnet beamline at the ESRF [J].
Livet, F ;
Bley, F ;
Létoublon, A ;
Simon, JP ;
Bérar, JF .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :1337-1345
[5]   Coherent X-ray study of fluctuations during domain coarsening [J].
Malik, A ;
Sandy, AR ;
Lurio, LB ;
Stephenson, GB ;
Mochrie, SGJ ;
McNulty, I ;
Sutton, M .
PHYSICAL REVIEW LETTERS, 1998, 81 (26) :5832-5835
[6]  
PIETSCH U, 2001, NUCL INSTRUM METH A, V1077, P467
[7]   Photon correlation spectroscopy:: X rays versus visible light [J].
Riese, DO ;
Vos, WL ;
Wegdam, GH ;
Poelwijk, FJ ;
Abernathy, DL ;
Grübel, G .
PHYSICAL REVIEW E, 2000, 61 (02) :1676-1680
[8]   On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation [J].
Snigirev, A ;
Snigireva, I ;
Kohn, V ;
Kuznetsov, S ;
Schelokov, I .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12) :5486-5492
[9]   Structure and dynamics of surfactant-stabilized aggregates of palladium nanoparticles under dilute and semidilute conditions:: Static and dynamic x-ray scattering [J].
Thurn-Albrecht, T ;
Meier, G ;
Müller-Buschbaum, P ;
Patkowski, A ;
Steffen, W ;
Grübel, G ;
Abernathy, DL ;
Diat, O ;
Winter, M ;
Koch, MG ;
Reetz, MT .
PHYSICAL REVIEW E, 1999, 59 (01) :642-649