Study of lung density corrections in a clinical trial (RTOG 88-08)

被引:28
作者
Orton, CG
Chungbin, S
Klein, EE
Gillin, MT
Schultheiss, TE
Sause, WT
机构
[1] Karmanos Canc Inst, Gershenson Radiat Oncol Ctr, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI USA
[3] Washington Univ, Med Ctr, Mallinckrodt Inst Radiol, Radiat Oncol Ctr, St Louis, MO 63110 USA
[4] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI USA
[5] Univ Texas, MD Anderson Cancer Ctr, Houston, TX 77030 USA
[6] LDS Hosp, Ctr Radiat, Salt Lake City, UT USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 41卷 / 04期
关键词
lung corrections; inhomogeneity corrections; clinical trials; lung densities; treatment planning; density corrections;
D O I
10.1016/S0360-3016(98)00117-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the effect of lung density corrections on the dose delivered to lung canter radiotherapy patients in a multi-institutional clinical trial, and to determine whether commonly available density-correction algorithms are sufficient to improve the accuracy and precision of dose calculation in the clinical trials setting. Methods and Materials: A benchmark problem was designed land a corresponding phantom fabricated) to test density-correction algorithms under standard conditions for photon beams ranging from Co-60 to, 24 MV. Point doses and isodose distributions submitted for a Phase III trial in regionally advanced, unresectable non-small-cell lung cancer (Radiation Therapy Oncology Group 88-08) were calculated with and without density correction. Tumor doses were analyzed for 322 patients and 1236 separate fields. Results: For the benchmark problem studied here, the overall correction factor for a four-held treatment varied significantly with energy, ranging from 1.14 (Co-60) to 1.05 (24 MV) for measured doses, or 1.17 (Co-60) to 1.05 (24 MV) for doses calculated by conventional density-correction algorithms. For the patient data, overall correction factors (calculated) ranged from 0.95 to 1.28, with a mean of 1.05 and distributional standard deviation of 0.05, The largest corrections were for lateral fields, with a mean correction factor of 1.11 and standard deviation of 0.08, Conclusions: Lung inhomogeneities can lead to significant variations in delivered dose between patients treated in a clinical trial. Existing density-correction algorithms are accurate enough to significantly reduce these variations. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:787 / 794
页数:8
相关论文
共 42 条
[1]   3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER [J].
ARMSTRONG, JG ;
BURMAN, C ;
LEIBEL, S ;
FONTENLA, D ;
KUTCHER, G ;
ZELEFSKY, M ;
FUKS, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04) :685-689
[3]  
BATHO H F, 1964, J Can Assoc Radiol, V15, P79
[4]   THE IMPLEMENTATION OF A GENERALIZED BATHO INHOMOGENEITY CORRECTION FOR RADIOTHERAPY PLANNING WITH DIRECT USE OF CT NUMBERS [J].
CASSELL, KJ ;
HOBDAY, PA ;
PARKER, RP .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (05) :825-833
[5]   A RANDOMIZED PHASE-I/II TRIAL OF HYPERFRACTIONATED RADIATION-THERAPY WITH TOTAL DOSES OF 60.0 GY TO 79.2 GY - POSSIBLE SURVIVAL BENEFIT WITH GREATER-THAN-OR-EQUAL-TO 69.6 GY IN FAVORABLE PATIENTS WITH RADIATION-THERAPY ONCOLOGY GROUP STAGE-III NON-SMALL-CELL LUNG-CARCINOMA - REPORT OF RADIATION-THERAPY ONCOLOGY GROUP 83-11 [J].
COX, JD ;
AZARNIA, N ;
BYHARDT, RW ;
SHIN, KH ;
EMAMI, B ;
PAJAK, TF .
JOURNAL OF CLINICAL ONCOLOGY, 1990, 8 (09) :1543-1555
[6]   N-2 (CLINICAL) NON-SMALL-CELL CARCINOMA OF THE LUNG - PROSPECTIVE TRIALS OF RADIATION-THERAPY WITH TOTAL DOSES 60 GY BY THE RADIATION-THERAPY-ONCOLOGY-GROUP [J].
COX, JD ;
AZARNIA, N ;
BYHARDT, RW ;
SHIN, KH ;
EMAMI, B ;
PEREZ, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (01) :7-12
[7]  
Cunningham JR, 1982, PROGR MED RAD PHYSIC, P103
[8]   PITFALLS IN THE USE OF HIGH-ENERGY X-RAYS TO TREAT TUMORS IN THE LUNG [J].
EKSTRAND, KE ;
BARNES, WH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :249-252
[9]   IMPROVED LUNG DOSE CALCULATION USING TISSUE MAXIMUM RATIOS IN THE BATHO CORRECTION [J].
ELKHATIB, E ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1984, 11 (03) :279-286
[10]   EVALUATION OF LUNG DOSE CORRECTION METHODS FOR PHOTON IRRADIATIONS OF THORAX PHANTOMS [J].
ELKHATIB, EE ;
EVANS, M ;
PLA, M ;
CUNNINGHAM, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (04) :871-878