Remote transfer of a high-stability and ultralow-jitter timing signal

被引:68
作者
Holman, KW [1 ]
Hudson, DD
Ye, J
Jones, DJ
机构
[1] Natl Inst Stand & Technol, Joint Inst Lab Astrophys, Boulder, CO 80309 USA
[2] Univ Colorado, Boulder, CO 80309 USA
[3] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z1, Canada
关键词
D O I
10.1364/OL.30.001225
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Transfer of a high-stability and ultralow-jitter timing signal through a fiber network via a mode-locked fiber laser is demonstrated. With active cancellation of the fiber-transmission noise, the fractional instability for transfer of a radio-frequency signal through a 6.9- (4.5-) km round-trip installed (laboratory-based) fiber network is below 9(7) x 10(-15) tau(-1/2) for an averaging time tau >= 1 s, limited by the noise floor of the frequency-counting system. The noise cancellation reduces the rms timing jitter, integrated over a bandwidth from 1 Hz to 100 kHz, to 37 (20) fs for the installed (laboratory-based) fiber network, representing what is to our knowledge the lowest reported jitter for transfer of a timing signal over kilometer-scale distances using an installed (laboratory-based) optical-fiber network. (c) 2005 Optical Society of America.
引用
收藏
页码:1225 / 1227
页数:3
相关论文
共 9 条
[1]   Sub-picosecond active timing control over fiber optic cable [J].
Celano, TP ;
Stein, SR ;
Mesander, BA ;
Ramsey, BJ .
PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION, 2002, :510-516
[2]   An optical clock based on a single trapped 199Hg+ ion [J].
Diddams, SA ;
Udem, T ;
Bergquist, JC ;
Curtis, EA ;
Drullinger, RE ;
Hollberg, L ;
Itano, WM ;
Lee, WD ;
Oates, CW ;
Vogel, KR ;
Wineland, DJ .
SCIENCE, 2001, 293 (5531) :825-828
[3]   Precise frequency transfer through a fiber network by use of 1.5-μm mode-locked sources [J].
Holman, KW ;
Jones, DJ ;
Hudson, DD ;
Ye, J .
OPTICS LETTERS, 2004, 29 (13) :1554-1556
[4]   Analysis of noise mechanisms limiting the frequency stability of microwave signals generated with a femtosecond laser [J].
Ivanov, EN ;
Diddams, SA ;
Hollberg, L .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2003, 9 (04) :1059-1065
[5]  
Karshenboim SG, 2000, CAN J PHYS, V78, P639, DOI 10.1139/cjp-78-7-639
[6]   Search for variations of fundamental constants using atomic fountain clocks -: art. no. 150801 [J].
Marion, H ;
Dos Santos, FP ;
Abgrall, M ;
Zhang, S ;
Sortais, Y ;
Bize, S ;
Maksimovic, I ;
Calonico, D ;
Grünert, J ;
Mandache, C ;
Lemonde, P ;
Santarelli, G ;
Laurent, P ;
Clairon, A ;
Salomon, C .
PHYSICAL REVIEW LETTERS, 2003, 90 (15) :4
[7]  
Primas L. E., 1989, Proceedings of the 43rd Annual Symposium on Frequency Control 1989 (Cat. No.89CH2690-6), P202, DOI 10.1109/FREQ.1989.68866
[8]   Transmission of low phase noise, low phase drift millimeter-wavelength references by a stabilized fiber distribution system [J].
Shillue, B ;
AlBanna, S ;
D'Addario, L .
2004 IEEE INTERNATIONAL TOPICAL MEETING ON MICROWAVE PHOTONICS, TECHNICAL DIGEST, 2004, :201-204
[9]   Molecular iodine clock [J].
Ye, J ;
Ma, LS ;
Hall, JL .
PHYSICAL REVIEW LETTERS, 2001, 87 (27) :270801-270801