Determination of As, Sb, Bi and Hg in water samples by flow-injection inductively coupled plasma mass spectrometry with an in-situ nebulizer/hydride generator

被引:33
作者
Chen, CS [1 ]
Jiang, SJ [1 ]
机构
[1] NATL SUN YAT SEN UNIV,DEPT CHEM,KAOHSIUNG 804,TAIWAN
关键词
antimony; arsenic; bismuth; flow injection; hydride generation; inductively coupled plasma mass spectrometer; mercury; water samples;
D O I
10.1016/S0584-8547(96)01564-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple and very inexpensive in-situ nebulizer/hydride generator was used with inductively coupled plasma mass spectrometry (ICP-MS) for the determination of As, Sb, Bi and Hg in water samples. The application of hydride generation ICP-MS alleviated the sensitivity problem of As, Sb, Bi and Hg determinations encountered when the conventional pneumatic nebulizer was used for sample introduction. The sample was introduced by flow injection to minimize the deposition of solids on the sampling orifice. The elements in the sample were reduced to the lower oxidation states with L-cysteine before being injected into the hydride generation system. This method has a detection limit of 0.003, 0.003, 0.017 and 0.17 ng ml(-1) for As, Bi, Sb and Hg, respectively. This method was applied to determine As, Sb, Bi and Hg in a CASS-3 nearshore seawater reference sample, a SLRS-2 riverine water reference sample and a tap water collected from National Sun Yat-Sen University. The concentrations of the elements were determined by standard addition method. The precision was better than 20% for most of the determinations.
引用
收藏
页码:1813 / 1821
页数:9
相关论文
共 37 条
[1]   SELECTIVE REDUCTION OF ARSENIC SPECIES BY CONTINUOUS HYDRIDE GENERATION .1. REACTION MEDIA [J].
ANDERSON, RK ;
THOMPSON, M ;
CULBARD, E .
ANALYST, 1986, 111 (10) :1143-1152
[2]   DETERMINATION OF TOTAL AND LEACHABLE ARSENIC AND SELENIUM IN SOILS BY CONTINUOUS HYDRIDE GENERATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
ANDERSON, STG ;
ROBERT, RVD ;
FARRER, HN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (10) :1107-1110
[3]   DETERMINATION OF TRACE-METALS IN A RIVER WATER REFERENCE MATERIAL BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
MYKYTIUK, AP ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :778-783
[5]   INTERFERENCE REDUCTION BY L-CYSTINE IN THE DETERMINATION OF ARSENIC BY HYDRIDE GENERATION [J].
BOAMPONG, C ;
BRINDLE, ID ;
LE, XC ;
PIDWERBESKY, L ;
PONZONI, CMC .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1185-1188
[6]   DETERMINATION OF URANIUM IN ENVIRONMENTAL-SAMPLES USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BOOMER, DW ;
POWELL, MJ .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2810-2813
[7]   DETERMINATION OF ARSENIC BY HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING A TUBULAR MEMBRANE GAS-LIQUID SEPARATOR [J].
BRANCH, S ;
CORNS, WT ;
EBDON, L ;
HILL, S ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :155-158
[8]   COMBINED GENERATOR/SEPARATOR FOR CONTINUOUS HYDRIDE GENERATION - APPLICATION TO ONLINE PRE-REDUCTION OF ARSENIC(V) AND DETERMINATION OF ARSENIC IN WATER BY ATOMIC EMISSION-SPECTROMETRY [J].
BRINDLE, ID ;
ALARABI, H ;
KARSHMAN, S ;
LE, XC ;
ZHENG, SG ;
CHEN, HW .
ANALYST, 1992, 117 (03) :407-411
[9]   CONVENIENT METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF GERMANIUM BY HYDRIDE GENERATION DIRECT-CURRENT PLASMA ATOMIC EMISSION-SPECTROMETRY - INTERFERENCE REDUCTION BY L-CYSTINE AND L-CYSTEINE [J].
BRINDLE, ID ;
LE, XC ;
LI, XF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (02) :227-232