Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer

被引:1072
作者
Berg, Wendie A. [1 ]
Blume, Jeffrey D. [2 ]
Cormack, Jean B. [2 ]
Mendelson, Ellen B. [3 ]
Lehrer, Daniel [4 ]
Bohm-Velez, Marcela [5 ]
Pisano, Etta D. [6 ]
Jong, Roberta A. [7 ]
Evans, W. Phil [8 ]
Morton, Marilyn J. [9 ]
Mahoney, Mary C. [10 ]
Larsen, Linda Hovanessian [11 ]
Barr, Richard G. [12 ]
Farria, Dione M. [13 ]
Marques, Helga S. [2 ]
Boparai, Karan [14 ]
机构
[1] Amer Radiol Serv Inc, John Hopkins Green Spring, Lutherville Timonium, MD USA
[2] Brown Univ, Ctr Stat Sci, Providence, RI 02912 USA
[3] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[4] CERIM, Buenos Aires, DF, Argentina
[5] Weinstein Imaging Assoc, Pittsburgh, PA USA
[6] Univ N Carolina, Sch Med, Chapel Hill, NC USA
[7] Univ Toronto, Sunnybrook & Womens Hosp, Toronto, ON, Canada
[8] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
[9] Mayo Clin, Rochester, MN USA
[10] Univ Cincinnati, Cincinnati, OH USA
[11] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
[12] Western Reserve Care Syst, Youngstown, OH USA
[13] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO USA
[14] Amer Coll Radiol, Philadelphia, PA USA
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 2008年 / 299卷 / 18期
关键词
D O I
10.1001/jama.299.18.2151
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context Screening ultrasound may depict small, node- negative breast cancers not seen on mammography. Objective To compare the diagnostic yield, defined as the proportion of women with positive screen test results and positive reference standard, and performance of screening with ultrasound plus mammography vs mammography alone in women at elevated risk of breast cancer. Design, Setting, and Participants From April 2004 to February 2006, 2809 women, with at least heterogeneously dense breast tissue in at least 1 quadrant, were recruited from 21 sites to undergo mammographic and physician- performed ultrasonographic examinations in randomized order by a radiologist masked to the other examination results. Reference standard was defined as a combination of pathology and 12- month follow-up and was available for 2637 ( 96.8%) of the 2725 eligible participants. Main Outcome Measures Diagnostic yield, sensitivity, specificity, and diagnostic accuracy ( assessed by the area under the receiver operating characteristic curve) of combined mammography plus ultrasound vs mammography alone and the positive predictive value of biopsy recommendations for mammography plus ultrasound vs mammography alone. Results Forty participants ( 41 breasts) were diagnosed with cancer: 8 suspicious on both ultrasound and mammography, 12 on ultrasound alone, 12 on mammography alone, and 8 participants ( 9 breasts) on neither. The diagnostic yield for mammography was 7.6 per 1000 women screened ( 20 of 2637) and increased to 11.8 per 1000 ( 31 of 2637) for combined mammography plus ultrasound; the supplemental yield was 4.2 per 1000 women screened ( 95% confidence interval [ CI], 1.1- 7.2 per 1000; P=. 003 that supplemental yield is 0). The diagnostic accuracy for mammography was 0.78 ( 95% CI, 0.67- 0.87) and increased to 0.91 ( 95% CI, 0.84- 0.96) for mammography plus ultrasound ( P=. 003 that difference is 0). Of 12 supplemental cancers detected by ultrasound alone, 11 ( 92%) were invasive with a median size of 10 mm( range, 5- 40 mm; mean [ SE], 12.6 [ 3.0] mm) and 8 of the 9 lesions ( 89%) reported had negative nodes. The positive predictive value of biopsy recommendation after full diagnostic workup was 19 of 84 for mammography ( 22.6%; 95% CI, 14.2%- 33%), 21 of 235 for ultrasound ( 8.9%, 95% CI, 5.6%- 13.3%), and 31 of 276 for combined mammography plus ultrasound ( 11.2%; 95% CI. 7.8%- 15.6%). Conclusions Adding a single screening ultrasound to mammography will yield an additional 1.1 to 7.2 cancers per 1000 high- risk women, but it will also substantially increase the number of false positives. Trial Registration clinicaltrials. gov Identifier: NCT00072501.
引用
收藏
页码:2151 / 2163
页数:13
相关论文
共 48 条
  • [1] Adams-Campbell LL, 2007, BREAST J, V13, P332, DOI 10.1111/j.1524-4741.2007.00439.x
  • [2] Lesion detection and characterization in a breast US phantom: Results of the ACRIN 6666 investigators
    Berg, WA
    Blume, JD
    Cormack, JB
    Mendelson, EB
    Madsen, EL
    [J]. RADIOLOGY, 2006, 239 (03) : 693 - 702
  • [3] Berg WA, 2004, AM J ROENTGENOL, V182, P34
  • [4] Supplemental screening sonography in dense breasts
    Berg, WA
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (05) : 845 - +
  • [5] Beyond standard mammographic screening: Mammography at age extremes, ultrasound, and MR imaging
    Berg, Wendie A.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2007, 45 (05) : 895 - +
  • [6] Operator dependence of physician-performed whole-breast US: Lesion detection and characterization
    Berg, Wendie A.
    Blume, Jeffrey D.
    Cormack, Jean B.
    Mendelson, Ellen B.
    [J]. RADIOLOGY, 2006, 241 (02) : 355 - 365
  • [7] Bondy Melissa L., 2003, Cancer, V97, P230, DOI 10.1002/cncr.11018
  • [8] Characterization of cysts using differential correlation coefficient values from two dimensional breast elastography: Preliminary study
    Booi, Rebecca C.
    Carson, Paul L.
    O'Donnell, Matthew
    Roubidoux, Marilyn A.
    Hall, Anne L.
    Rubin, Jonathan M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (01) : 12 - 21
  • [9] Interexamination variation of whole breast ultrasound
    Bosch, AM
    Kessels, AGH
    Beets, GL
    Vranken, KLCG
    Borstlap, AC
    Von Meyenfeldt, MF
    van Engelshoven, JMA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (905) : 328 - 331
  • [10] Mammographic density and the risk and detection of breast cancer
    Boyd, Norman F.
    Guo, Helen
    Martin, Lisa J.
    Sun, Limei
    Stone, Jennifer
    Fishell, Eve
    Jong, Roberta A.
    Hislop, Greg
    Chiarelli, Anna
    Minkin, Salomon
    Yaffe, Martin J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (03) : 227 - 236