Relationship Between Interstitial and Blood Glucose During Hypoglycemia in Subjects with Type 2 Diabetes

被引:8
作者
Choudhary, Pratik [1 ]
Lonnen, Kathryn [3 ]
Emery, Celia J. [1 ]
Freeman, Jenny V. [2 ]
McLeod, Ken M. [3 ]
Heller, Simon R. [1 ]
机构
[1] Univ Sheffield, Acad Unit Diabet Endocrinol & Metab, Sheffield, S Yorkshire, England
[2] Univ Sheffield, Sch Hlth & Related Res, Sheffield, S Yorkshire, England
[3] Peninsula Med Sch, Dept Diabet & Vasc Med, Exeter, Devon, England
关键词
MONITORING-SYSTEM; PLASMA-GLUCOSE; INSULIN; VALUES; CGMS;
D O I
10.1089/dia.2011.0059
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Continuous glucose monitoring devices measure interstitial glucose and are commonly used to investigate hypoglycemia. The relationship between interstitial glucose and blood glucose is not completely understood, particularly at low blood glucose concentrations. Interstitial glucose during hypoglycemia is generally lower than blood glucose in young subjects without diabetes and those with type 1 diabetes, but the effect of insulin resistance and obesity in type 2 diabetes on this relationship has not been examined previously. We studied the relationship between blood and interstitial glucose during experimental hypoglycemia in subjects with type 2 diabetes treated with insulin or sulfonylureas and matched controls without diabetes. Methods: Twenty subjects with type 2 diabetes (10 sulfonylurea-treated and 10 insulin-treated) and 10 controls without diabetes of similar age and weight underwent stepped hyperinsulinemic hypoglycemic clamps. We compared blood and interstitial glucose at different levels of hypoglycemia using random effects modeling. Results: Interstitial glucose was significantly higher than blood glucose at all levels of hypoglycemia (P < 0.001), and this difference increased as glucose fell. For every 1 mmol/L drop in blood glucose, the difference increased by 0.32 mmol/L (P < 0.001). This difference was not affected by presence of type 2 diabetes or by modality of treatment (P = 0.10). Conclusions: In older subjects with or without type 2 diabetes, interstitial glucose is significantly higher than blood glucose, and this difference increases with increasing severity of hypoglycemia. Continuous glucose monitors may underestimate hypoglycemia in this group, and this should be taken into account when interpreting results obtained using this technology.
引用
收藏
页码:1121 / 1127
页数:7
相关论文
共 23 条
[1]   Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring [J].
Aussedat, B ;
Dupire-Angel, M ;
Gifford, R ;
Klein, JC ;
Wilson, GS ;
Reach, G .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04) :E716-E728
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Subcutaneous glucose sensor values closely parallel blood glucose during insulin-induced hypoglycaemia [J].
Caplin, NJ ;
O'Leary, P ;
Bulsara, M ;
Davis, EA ;
Jones, TW .
DIABETIC MEDICINE, 2003, 20 (03) :238-241
[4]  
Cheyne E H, 2002, Diabetes Technol Ther, V4, P607, DOI 10.1089/152091502320798222
[5]   Comparing hormonal and symptomatic responses to experimental hypoglycaemia in insulin- and sulphonylurea-treated Type 2 diabetes [J].
Choudhary, P. ;
Lonnen, K. ;
Emery, C. J. ;
MacDonald, I. A. ;
MacLeod, K. M. ;
Amiel, S. A. ;
Heller, S. R. .
DIABETIC MEDICINE, 2009, 26 (07) :665-672
[6]  
DE MG, 2009, ACTA DIABETOL, V46, P67
[7]  
Diabetes Research in Children Network (DIRECNET) Study Group, 2003, Diabetes Technol Ther, V5, P781
[8]   Risk of hypoglycaemia in types 1 and 2 diabetes: effects of treatment modalities and their duration [J].
Heller, S. R. ;
Choudhary, P. ;
Davies, C. ;
Emery, C. ;
Campbell, M. J. ;
Freeman, J. ;
Amiel, S. A. ;
Malik, R. ;
Frier, B. M. ;
Allen, K. V. ;
Zammitt, N. N. ;
Macleod, K. ;
Lonnen, K. F. ;
Kerr, D. ;
Richardson, T. ;
Hunter, S. ;
Mclaughlin, D. .
DIABETOLOGIA, 2007, 50 (06) :1140-1147
[9]   A pilot study of the continuous glucose monitoring system - Clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects [J].
Kaufman, FR ;
Gibson, LC ;
Halvorson, M ;
Carpenter, S ;
Fisher, LK ;
Pitukcheewanont, P .
DIABETES CARE, 2001, 24 (12) :2030-2034
[10]   ARTERIAL, ARTERIALIZED VENOUS, VENOUS AND CAPILLARY BLOOD-GLUCOSE MEASUREMENTS IN NORMAL MAN DURING HYPERINSULINEMIC EUGLYCEMIA AND HYPOGLYCEMIA [J].
LIU, D ;
MOBERG, E ;
KOLLIND, M ;
LINS, PE ;
ADAMSON, U ;
MACDONALD, IA .
DIABETOLOGIA, 1992, 35 (03) :287-290