Visualization of solute migration in liquid chromatography columns

被引:28
作者
Shalliker, RA
Broyles, BS
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
detection; LC; visualization of solute migration; solute migration;
D O I
10.1016/S0021-9673(98)00734-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
By matching the refractive indices of the mobile phase, the stationary phase and the material of the bed enclosure, one can render transparent to the eye the chromatographic column which is normally opaque in nature. As a result, band visualization is readily obtained. High-definition on-column detection becomes feasible by using a photographic detector instead of the conventional post-column, on-line (UV-Vis or similar) detector. Quantitative information regarding the concentration distribution in the band is obtained by utilizing optical scanners to obtain a digital image and computer imaging software. The processes of data collection and image analysis are discussed in detail and are illustrated by observing the concept of the infinite diameter column following a central point injection. The performance of the photographic detection method is compared to that of regular detection procedures. The efficiency of the column was determined with both on-column measurements and regular post-column measurements. A minimum reduced plate height (h) of 1.9 was recorded with post-column detection, in agreement with the average of the results given by on column detection. On-column analysis allowed the determination of the local plate height which was found to vary across the central region of the column between 2.7 and 0.95. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 22 条
[1]   MICROCYLINDER ELECTRODES AS SENSITIVE DETECTORS FOR HIGH-EFFICIENCY, HIGH-SPEED LIQUID-CHROMATOGRAPHY [J].
BAUR, JE ;
WIGHTMAN, RM .
JOURNAL OF CHROMATOGRAPHY, 1989, 482 (01) :65-73
[2]   RADIAL DISPERSION FROM COMMERCIAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS INVESTIGATED WITH MICROVOLTAMMETRIC ELECTRODES [J].
BAUR, JE ;
KRISTENSEN, EW ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2334-2338
[3]  
BROYLES BS, IN PRESS J CHROMAT A
[4]   Chemical imaging of multicomponent viscous fingering in chromatography [J].
Dickson, ML ;
Norton, TT ;
Fernandez, EJ .
AICHE JOURNAL, 1997, 43 (02) :409-418
[5]   COMPARISON OF BROADENING PATTERNS IN REGULAR AND RADIALLY COMPRESSED LARGE-DIAMETER COLUMNS [J].
EON, CH .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :29-42
[6]   Column radial homogeneity in high-performance liquid chromatography [J].
Farkas, T ;
Sepaniak, MJ ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (02) :169-181
[7]   Contribution of the radial distribution of the flow velocity to band broadening in HPLC columns [J].
Farkas, T ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4592-4600
[8]   Radial distribution of the flow velocity, efficiency and concentration in a wide HPLC column [J].
Farkas, T ;
Sepaniak, MJ ;
Guiochon, G .
AICHE JOURNAL, 1997, 43 (08) :1964-1974
[9]   COLUMN EFFICIENCY AND RADIAL HOMOGENEITY IN LIQUID-CHROMATOGRAPHY [J].
FARKAS, T ;
CHAMBERS, JQ ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 679 (02) :231-245
[10]   A column design for reducing viscous fingering in size exclusion chromatography [J].
Fernandez, EJ ;
Norton, TT ;
Jung, WC ;
Tsavalas, JG .
BIOTECHNOLOGY PROGRESS, 1996, 12 (04) :480-487