CT Angiography of the Aorta Is Superior to Transesophageal Echocardiography for Determining Stroke Subtypes in Patients with Cryptogenic Ischemic Stroke

被引:40
作者
Chatzikonstantinou, A. [1 ]
Krissak, R. [2 ]
Fluechter, S. [3 ]
Artemis, D. [1 ]
Schaefer, A. [1 ]
Schoenberg, S. O. [2 ]
Hennerici, M. G. [1 ]
Fink, C. [2 ]
机构
[1] Univ Heidelberg, Univ Med Mannheim, Dept Neurol, DE-68167 Mannheim, Germany
[2] Univ Heidelberg, Univ Med Mannheim, Inst Radiol & Nucl Med, DE-68167 Mannheim, Germany
[3] Univ Heidelberg, Univ Med Mannheim, Dept Cardiol, DE-68167 Mannheim, Germany
关键词
Acute ischemic stroke; Cryptogenic stroke; CT angiography; Transesophageal echocardiography; Aorta; Aortic atherosclerosis; THORACIC AORTA; ARCH; PLAQUES; CLASSIFICATION; POPULATION; MORPHOLOGY; ATHEROMA; EMBOLISM; DISEASE; EVENTS;
D O I
10.1159/000335828
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The etiology of ischemic strokes remains cryptogenic in about one third of patients, even after extensive workup in specialized centers. Atherosclerotic plaques in the aorta can cause thromboembolic events but are often overlooked. They can elude standard identification by transesophageal echocardiography (TEE), which is invasive or at best uncomfortable for many patients. CT angiography (CTA) can be used as an alternative or in addition to TEE if this technique fails to visualize every part of the aorta and in particular the aortic arch. Methods: We prospectively studied 64 patients (47 men, age 60 8 13 years) classified as having cryptogenic stroke after standard and full workup [including brain MRI and 24-hour electrocardiogram (ECG)] with ECG-triggered CTA of the aorta in search of plaques and compared the results with those of TEE. Investigators were blinded to the results of both techniques. Plaques were graded on CTA according to their presence (0 = not present; 1 = mild; 2 = severe) and degree of calcification (1a or 2a = noncalcified; 1b or 2b = calcified). Associations with risk factors and infarct localization were also assessed. Results: Only 21 of 64 patients (32.8%) had aortic plaques identified by TEE, compared to 43 of 64 (67.2%) with CTA (p < 0.05). The plaque localization was as follows (TEE vs. CTA): ascending aorta, 10 vs. 20 (p < 0.05); aortic arch, 10 vs. 40 (p < 0.05), and descending aorta, 20 vs. 34 (p < 0.05). Grade 1 plaques were most commonly found in the aortic arch (25; 39%), while grade 2 plaques were most often detected in the aortic arch (15; 23.4%) and the descending aorta (14; 21.9%). There was no significant correlation between plaque location, infarct territory or vascular risk profile, except for hypertension (p = 0.003), which was significantly associated with the presence of plaques. Conclusions: CTA identifies more plaques throughout the aortic arch and around the origins of the major cerebral arteries in particular compared to TEE. These may represent potential embolic sources of acute ischemic stroke. Better plaque detection may have an impact on the best available secondary prevention regimen in individual patients if proximal embolic sources are suspected. Copyright (C) 2012 S. Karger AG, Basel
引用
收藏
页码:322 / 328
页数:7
相关论文
共 27 条
  • [1] MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose
    Abada, Hicham T.
    Larchez, Christophe
    Daoud, Beatrice
    Sigal-Cinqualbre, Anne
    Paul, Jean-Francois
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) : S387 - S390
  • [2] CLASSIFICATION OF SUBTYPE OF ACUTE ISCHEMIC STROKE - DEFINITIONS FOR USE IN A MULTICENTER CLINICAL-TRIAL
    ADAMS, HP
    BENDIXEN, BH
    KAPPELLE, LJ
    BILLER, J
    LOVE, BB
    GORDON, DL
    MARSH, EE
    KASE, CS
    WOLF, PA
    BABIKIAN, VL
    LICATAGEHR, EE
    ALLEN, N
    BRASS, LM
    FAYAD, PB
    PAVALKIS, FJ
    WEINBERGER, JM
    TUHRIM, S
    RUDOLPH, SH
    HOROWITZ, DR
    BITTON, A
    MOHR, JP
    SACCO, RL
    CLAVIJO, M
    ROSENBAUM, DM
    SPARR, SA
    KATZ, P
    KLONOWSKI, E
    CULEBRAS, A
    CAREY, G
    MARTIR, NI
    FICARRA, C
    HOGAN, EL
    CARTER, T
    GURECKI, P
    MUNTZ, BK
    RAMIREZLASSEPAS, M
    TULLOCH, JW
    QUINONES, MR
    MENDEZ, M
    ZHANG, SM
    ALA, T
    JOHNSTON, KC
    ANDERSON, DC
    TARREL, RM
    NANCE, MA
    BUDLIE, SR
    DIERICH, M
    HELGASON, CM
    HIER, DB
    SHAPIRO, RA
    [J]. STROKE, 1993, 24 (01) : 35 - 41
  • [3] Relation of coronary artery disease and cerebrovascular disease with atherosclerosis of the thoracic aorta in the general population
    Agmon, Y
    Khandheria, BK
    Meissner, I
    Schwartz, GL
    Petterson, TM
    O'Fallon, WM
    Whisnant, JP
    Wiebers, DO
    Seward, JB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (03) : 262 - 267
  • [4] ATHEROSCLEROTIC DISEASE OF THE AORTIC-ARCH AND THE RISK OF ISCHEMIC STROKE
    AMARENCO, P
    COHEN, A
    TZOURIO, C
    BERTRAND, B
    HOMMEL, M
    BESSON, G
    CHAUVEL, C
    TOUBOUL, PJ
    BOUSSER, MG
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (22) : 1474 - 1479
  • [5] New Approach to Stroke Subtyping: The A-S-C-O (Phenotypic) Classification of Stroke
    Amarenco, P.
    Bogousslavsky, J.
    Caplan, L. R.
    Donnan, G. A.
    Hennerici, M. G.
    [J]. CEREBROVASCULAR DISEASES, 2009, 27 (05) : 502 - 508
  • [6] THE PREVALENCE OF ULCERATED PLAQUES IN THE AORTIC-ARCH IN PATIENTS WITH STROKE
    AMARENCO, P
    DUYCKAERTS, C
    TZOURIO, C
    HENIN, D
    BOUSSER, MG
    HAUW, JJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (04) : 221 - 225
  • [7] Cohen A, 1997, CIRCULATION, V96, P3838
  • [8] Use of automatic exposure control in multislice computed tomography of the coronaries:: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography
    Deetjen, Anja
    Moellmann, Susanne
    Conradi, Guido
    Rolf, Andreas
    Schmermund, Axel
    Hamm, Christian W.
    Dill, Thorsten
    [J]. HEART, 2007, 93 (09) : 1040 - 1043
  • [9] Aortic Arch Plaques and Risk of Recurrent Stroke and Death
    Di Tullio, Marco R.
    Russo, Cesare
    Jin, Zhezhen
    Sacco, Ralph L.
    Mohr, J. P.
    Homma, Shunichi
    [J]. CIRCULATION, 2009, 119 (17) : 2376 - 2382
  • [10] European guidelines on quality criteria for computed tomography, 1999, 16262 EUR