Standardized measurements and differential spectroscopy in microplates

被引:10
作者
Geiger, G [1 ]
Bernhagen, J
Wagner, E
Bisswanger, H
Brunner, H
Vitzthum, F
机构
[1] Univ Stuttgart, Inst Interfacial Engn, Biochem Lab, D-70569 Stuttgart, Germany
[2] Fraunhofer IGB, D-70569 Stuttgart, Germany
[3] Univ Tubingen, Inst Physiol Chem, D-72076 Tubingen, Germany
关键词
pathlength; standardization; differential spectroscopy; evaporation; cross-contamination; microplate; lid;
D O I
10.1006/abio.2001.5231
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microplates (MPs) are excellent devices for the parallel processing of multiple samples for the spectroscopic analysis of chromophores and turbidity, for luminometric measurements, for cell culture applications, or simply for sample storage, library organization, and other high-throughput (HTP) processes. Disadvantages include an ill-defined pathlength, meniscus formation, evaporation, and cross-contamination. Here, we have developed a novel MP and lid system which can serve to minimize these drawbacks. Cup-like lids are inserted into MP wells. Thereby, liquid is pushed aside. The flat bottoms of the cup-like lids guarantee a planar interface and a defined pathlength. In addition, the devised MF system allows for differential spectroscopic analysis of multiple samples comparable to measurements in tandem cuvettes. This was shown by the investigation of the binding of reduced nicotinamide adenine dinucleotide to dihydrolipoamide dehydrogenase. The MP lid system described offers a low-cost solution for standardized spectrophotometric quantitations in any solvent compatible with the MP/lid material. In addition to the system's suitability for routine MP application, it should be advantageous as a simple and noninvasive method, i.e., no labeling and immobilization of analytes is required for detection of the interaction of molecules, for various HTP applications and drug screening purposes. (C) 2001 Academic Press.
引用
收藏
页码:29 / 40
页数:12
相关论文
共 55 条
[1]   ULTRAFAST PROTEIN DETERMINATIONS USING MICROWAVE ENHANCEMENT [J].
AKINS, RE ;
TUAN, RS .
MOLECULAR BIOTECHNOLOGY, 1995, 4 (01) :17-24
[2]  
AKINS RE, 1992, BIOTECHNIQUES, V12, P496
[3]  
BARRENSCHEEN HK, 1941, Z PHYSL CHEM, V272, P81
[4]  
Bisswanger H., 1994, ENZYMKINETIK THEORIE
[5]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[6]  
BRUNNER H, 2000, Patent No. 0001121
[7]  
BRUNNER H, 2000, Patent No. 0049393
[8]   In search of the final sink [J].
Brunner, PH .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 1999, 6 (01) :1-1
[10]   INSULIN DEGRADATION .15. USE OF DIFFERENT ASSAY METHODS FOR STUDY OF MECHANISM OF ACTION OF GLUTATHIONE-INSULIN TRANSHYDROGENASE [J].
CHANDLER, ML ;
VARANDANI, PT .
BIOCHIMICA ET BIOPHYSICA ACTA, 1975, 397 (02) :307-317