Deformation Dynamics and Mechanical Properties of the Aortic Annulus by 4-Dimensional Computed Tomography

被引:145
作者
Hamdan, Ashraf [1 ,2 ,3 ,4 ]
Guetta, Victor [1 ,2 ]
Konen, Eli [3 ,4 ]
Goitein, Orly [3 ,4 ]
Segev, Amit [1 ,2 ]
Raanani, Ehud [4 ,5 ]
Spiegelstein, Dan [4 ,5 ]
Hay, Ilan [1 ,2 ]
Di Segni, Elio [1 ,2 ,3 ,4 ]
Eldar, Michael [1 ,2 ]
Schwammenthal, Ehud [1 ,2 ]
机构
[1] Chaim Sheba Med Ctr, Ctr Heart, IL-52621 Tel Hashomer, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-52621 Tel Hashomer, Israel
[3] Chaim Sheba Med Ctr, Dept Radiol, IL-52621 Tel Hashomer, Israel
[4] Tel Aviv Univ, Sackler Fac Med, Tel Hashomer, Israel
[5] Chaim Sheba Med Ctr, Dept Cardiac Surg, IL-52621 Tel Hashomer, Israel
关键词
aortic annulus; computed tomography; transcatheter aortic valve implantation; OUTFLOW TRACT ECCENTRICITY; VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; REPLACEMENT; DIMENSIONS; ROOT;
D O I
10.1016/j.jacc.2011.09.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to assess deformation dynamics and in vivo mechanical properties of the aortic annulus throughout the cardiac cycle. Background Understanding dynamic aspects of functional aortic valve anatomy is important for beating-heart transcatheter aortic valve implantation. Methods Thirty-five patients with aortic stenosis and 11 normal subjects underwent 256-slice computed tomography. The aortic annulus plane was reconstructed in 10% increments over the cardiac cycle. For each phase, minimum diameter, ellipticity index, cross-sectional area (CSA), and perimeter (Perim) were measured. In a subset of 10 patients, Young's elastic module was calculated from the stress-strain relationship of the annulus. Results In both subjects with normal and with calcified aortic valves, minimum diameter increased in systole (12.3 +/- 7.3% and 9.8 +/- 3.4%, respectively; p < 0.001), and ellipticity index decreased (12.7 +/- 8.8% and 10.3 +/- 2.7%, respectively; p < 0.001). The CSA increased by 11.2 +/- 5.4% and 6.2 +/- 4.8%, respectively (p < 0.001). Perim increase was negligible in patients with calcified valves (0.56 +/- 0.85%; p < 0.001) and small even in normal subjects (2.2 +/- 2.2%; p = 0.01). Accordingly, relative percentage differences between maximum and minimum values were significantly smallest for Perim compared with all other parameters. Young's modulus was calculated as 22.6 +/- 9.2 MPa in patients and 13.8 +/- 6.4 MPa in normal subjects. Conclusions The aortic annulus, generally elliptic, assumes a more round shape in systole, thus increasing CSA without substantial change in perimeter. Perimeter changes are negligible in patients with calcified valves, because tissue properties allow very little expansion. Aortic annulus perimeter appears therefore ideally suited for accurate sizing in transcatheter aortic valve implantation. (J Am Coll Cardiol 2012; 59: 119-27) (C) 2012 by the American College of Cardiology Foundation
引用
收藏
页码:119 / 127
页数:9
相关论文
共 21 条
[1]  
An KN, 2004, BIORHEOLOGY, V41, P239
[2]  
Anderson Robert H, 2007, Multimed Man Cardiothorac Surg, V2007, DOI 10.1510/mmcts.2006.002527
[3]  
Bird J., 2002, Mechanical engineering principles
[4]   Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method [J].
Blanke, Philipp ;
Siepe, Matthias ;
Reinoehl, Jochen ;
Zehender, Manfred ;
Beyersdorf, Friedhelm ;
Schlensak, Christian ;
Langer, Mathias ;
Pache, Gregor .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (06) :750-758
[5]  
da Vinci Leonardo, 2005, NOTES VALVES HEART F
[6]   Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence [J].
Detaint, Delphine ;
Lepage, Laurent ;
Himbert, Dominique ;
Brochet, Eric ;
Messika-Zeitoun, David ;
Iung, Bernard ;
Vahanian, Alec .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :821-827
[7]   Demonstration of left ventricular outflow tract eccentricity by real time 3D echocardiography: Implications for the determination of aortic valve area [J].
Doddamani, Sanjay ;
Bello, Ricardo ;
Friedman, Mark A. ;
Banerjee, Anita ;
Bowers, James H., Jr. ;
Kim, Bette ;
Vennalaganti, Prashant R. ;
Ostfeld, Robert J. ;
Gordon, Garet M. ;
Malhotra, Divya ;
Spevack, Daniel M. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (08) :860-866
[8]   Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT [J].
Doddamani, Sanjay ;
Grushko, Michael J. ;
Makaryus, Amgad N. ;
Jain, Vineet R. ;
Bello, Ricardo ;
Friedman, Mark A. ;
Ostfeld, Robert J. ;
Malhotra, Divya ;
Boxt, Lawrence M. ;
Haramati, Linda ;
Spevack, Daniel M. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (02) :175-181
[9]   Three-dimensional regional dynamics of the normal mitral anulus during left ventricular ejection [J].
Glasson, JR ;
Komeda, M ;
Daughters, GT ;
Niczyporuk, MA ;
Bolger, AF ;
Ingels, NB ;
Miller, DC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (03) :574-584
[10]   Dynamic balance of the aortomitral junction [J].
Lansac, E ;
Hiang, K ;
Shomura, Y ;
Goetz, WA ;
Sen Lim, H ;
Rice, NT ;
Saber, H ;
Duran, CMG ;
Sen, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (05) :911-918