Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis

被引:47
作者
Dougherty, G
机构
[1] Faculty of Allied Health Sciences, Kuwait University, Sulaibikhat 90805
关键词
osteoporosis; computed tomography (CT); bone structure; texture; fracture risk;
D O I
10.1016/1350-4533(96)00011-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The biomechanical strength of the skeleton, and hence the risk of future fractures, depends on both the bone quantity (assessed in terms of bone mineral density) and Done quality (assessed in terms of the integrity of its internal architecture). Precise methods of measuring the calcium-equivalent density of both the trabecular and cortical components of vertebral bone using quantitative computed tomography are presented. For a group of Post-menopausal Kuwaiti females, we have shown that the trabecular and cortical components are highly correlated with each other at both the L3 and L4 lumbar vertebral levels, with correlation coefficients of 0.78 and 0.74 (P < 0.0001) respectively. We have explored the anisotropic distribution of trabecular bone and considered the use of the standard deviation and the coefficient of variation of trabecular CT numbers as texture Indicators and surrogate measures of bone quality. The coefficient of variation was the better texture indicator: used with bone mineral density values it successfully discriminated between two classes of patients (those with fractures and those without) with high sensitivity (greater than or equal to 89%) and specificity (greater than or equal to 82%). Copyright (C) 1996 Elsevier Science Ltd for IPEMB.
引用
收藏
页码:557 / 568
页数:12
相关论文
共 37 条
[1]  
ARNOLD JS, 1970, PROGR METHODS BONE M, P352
[2]   CLINICAL DETERMINATION OF BONE QUALITY - IS ULTRASOUND AN ANSWER [J].
BRANDENBURGER, GH ;
PIERCE ;
HEANEY ;
SCHNITZLER .
CALCIFIED TISSUE INTERNATIONAL, 1993, 53 :S151-S156
[3]   MULTIFRACTAL RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS [J].
CALIGIURI, P ;
GIGER, ML ;
FAVUS, M .
MEDICAL PHYSICS, 1994, 21 (04) :503-508
[4]   QUANTITATIVE CT FOR DETERMINATION OF BONE-MINERAL DENSITY - A REVIEW [J].
CANN, CE .
RADIOLOGY, 1988, 166 (02) :509-522
[5]   QUANTITATIVE COMPUTED-TOMOGRAPHY FOR PREDICTION OF VERTEBRAL FRACTURE RISK [J].
CANN, CE ;
GENANT, HK ;
KOLB, FO ;
ETTINGER, B .
BONE, 1985, 6 (01) :1-7
[6]  
CANN CE, 1985, J COMPUT ASSIST TOMO, V9, P616
[7]   FRACTAL ANALYSIS OF TRABECULAR PATTERNS IN PROJECTION RADIOGRAPHS - AN ASSESSMENT [J].
CHEN, J ;
ZHENG, B ;
CHANG, YH ;
SHAW, CC ;
TOWERS, JD ;
GUR, D .
INVESTIGATIVE RADIOLOGY, 1994, 29 (06) :624-629
[8]  
CODY DD, 1988, RADIOLOGY P, V169, P194
[9]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[10]   THE ASSESSMENT OF VERTEBRAL BONE MACROARCHITECTURE WITH X-RAY COMPUTED-TOMOGRAPHY [J].
FLYNN, MJ ;
CODY, DD .
CALCIFIED TISSUE INTERNATIONAL, 1993, 53 :S170-S175