Percutaneous renal biopsy in children:: A 27-year experience

被引:48
作者
Feneberg, R
Schafer, F
Zieger, B
Waldherr, R
Mehls, O
Schärer, K
机构
[1] Univ Heidelberg, Div Pediat Nephrol, D-6900 Heidelberg, Germany
[2] Univ Heidelberg, Dept Pediat Radiol, D-6900 Heidelberg, Germany
[3] Univ Heidelberg, Dept Pathol, D-6900 Heidelberg, Germany
关键词
Automated biopsy device; children; complications; biopsy; quality assessment; renal biopsy; ultrasound guidance;
D O I
10.1159/000045090
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: The introduction of automated biopsy devices and the localization of the kidney by ultrasound were aimed at optimizing efficacy and safety of the percutaneous renal biopsy procedure. We evaluated these technological advances in our renal biopsies performed in children. Methods: We sequentially used the Silverman needle (1969-1974), the TruCut needle (1974-1990), and the automated Biopty device (1990-1996). Fluoroscopy was used to localize the kidney until 1985, ultrasound examination prior to biopsy from 1985 to 1992, and direct ultrasound guidance since 1992. A total of 962 native kidney biopsies and 119 allograft biopsies were performed. Results: In the native kidney biopsies, the introduction of the Biopty device and ultrasound guidance were independently associated with fewer passes required to obtain adequate tissue and more glomeruli per specimen. The rate of biopsies yielding more than 9 glomeruli increased from 69 to 92% (p < 0.05). The number of glomeruli harvested per centimeter core length was inversely related to patient age (p < 0.01). More appropriate cortical tissue was retrieved in renal allograft biopsy specimens with the application of the new techniques. The occurrence of macroscopic hematuria (9.6%) in the native kidney biopsies was not affected by the puncture or localization technique applied, but subcapsular hematomas were documented more often with the Biopty device (42%) than with the TruCut needle (16%), probably due to improved ultrasound equipment. In the whole series 2 patients died, and 3 others required renal surgery and 4 blood transfusions. Conclusions: The automated ultrasound-guided procedure is a feasible and reliable technique for percutaneous renal biopsy in children. It gives a greater yield of diagnostic tissue without increasing the rate of clinical complications.
引用
收藏
页码:438 / 446
页数:9
相关论文
共 41 条
[1]   THE OUTCOME OF PERCUTANEOUS RENAL BIOPSY IN CHILDREN - AN ANALYSIS OF 120 CONSECUTIVE CASES [J].
ALRASHEED, SA ;
ALMUGEIREN, MM ;
ABDURRAHMAN, MB ;
ELIDRISSY, ATH .
PEDIATRIC NEPHROLOGY, 1990, 4 (06) :600-603
[2]   PERCUTANEOUS RENAL BIOPSY WITH REAL-TIME ULTRASONOGRAPHY [J].
BACKMAN, U ;
LINDGREN, PG .
SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1982, 16 (01) :65-67
[3]   COMPARISON OF 3 METHODS TO OBTAIN PERCUTANEOUS NEEDLE CORE BIOPSIES OF A RENAL-ALLOGRAFT [J].
BECKINGHAM, IJ ;
NICHOLSON, ML ;
KIRK, G ;
VEITCH, PS ;
BELL, PRF .
BRITISH JOURNAL OF SURGERY, 1994, 81 (06) :898-899
[4]  
BONDESTAM S, 1992, SCAND J UROL NEPHROL, V26, P165
[5]  
CAMERON JS, 1997, AM J NEPHROL, V17, P348
[6]  
CARVAJAL HF, 1971, TEX REP BIOL MED, V29, P253
[7]   RENAL BIOPSIES UNDER ULTRASOUND GUIDANCE - 100 CONSECUTIVE BIOPSIES IN CHILDREN [J].
CHAN, JCM ;
BREWER, WH ;
STILL, WJ .
JOURNAL OF UROLOGY, 1983, 129 (01) :103-107
[8]  
CHURG J, 1970, LANCET, V1, P1299
[9]  
Churg J., 1982, RENAL DIS CLASSIFICA
[10]   CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY [J].
COZENS, NJA ;
MURCHISON, JT ;
ALLAN, PL ;
WINNEY, RJ .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775) :594-597