Sensitive stripping voltammetry of heavy metals by using a composite sensor based on a built-in bismuth precursor

被引:55
作者
Castañeda, MT [1 ]
Pérez, B [1 ]
Pumera, M [1 ]
del Valle, M [1 ]
Merkoçi, A [1 ]
Alegret, S [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Quim, Grp Sensors & Biosensors, Bellaterra 08193, Catalonia, Spain
关键词
D O I
10.1039/b502486m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new graphite - epoxy composite electrode (GECE) containing Bi(NO3)(3) as a built-in bismuth precursor for simultaneous and individual anodic stripping analysis of heavy trace metals like lead and cadmium is reported. The developed Bi(NO3)(3)-GECE is compatible with bismuth film electrodes reported previously including the composite electrodes (Bi-GECE) recently reported by our group. Bi(NO3)(3)-GECE displays the ability for the detection of both individual and simultaneous determination of heavy trace metals and exhibits well defined, reproducible and sharp stripping signals. The sensitive response is combined with the minimal toxicity of Bi(NO3)(3). This novel sensor would be an appropriate alternative tool to sensors using bismuth in solution during their utilization in environmental quality monitoring as well as other applications.
引用
收藏
页码:971 / 976
页数:6
相关论文
共 42 条
[1]   Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters [J].
Achterberg, EP ;
Braungardt, C .
ANALYTICA CHIMICA ACTA, 1999, 400 :381-397
[2]   Rigid carbon - Polymer biocomposites for electrochemical sensing - A review [J].
Alegret, S .
ANALYST, 1996, 121 (12) :1751-1758
[3]  
Alegret S., 1999, QUIM ANAL, V23, P18
[4]  
Alegret S, 2003, INTEGRATED ANAL SYST, P377
[5]   Gold electrodes from recordable CDs [J].
Angnes, L ;
Richter, EM ;
Augelli, MA ;
Kume, GH .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5503-5506
[6]   Anodic stripping voltammetry at bismuth-coated and uncoated carbon microdisk electrodes: Application to trace metals analysis in food samples [J].
Baldo, MA ;
Daniele, S .
ANALYTICAL LETTERS, 2004, 37 (05) :995-1011
[7]   Application of graphite-epoxy composite electrodes in differential pulse anodic stripping voltammetry of heavy metals [J].
Carrégalo, S ;
Merkoçi, A ;
Alegret, S .
MICROCHIMICA ACTA, 2004, 147 (04) :245-251
[8]   New materials for electrochemical sensing -: II.: Rigid carbon-polymer biocomposites [J].
Céspedes, F ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (04) :276-285
[9]   New materials for electrochemical sensing .1. Rigid conducting composites [J].
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :296-304
[10]   VOLTAMMETRIC RESPONSE OF DIMETHYL-SULFOXIDE AT GOLD ELECTRODES MODIFIED BY THIN-FILMS OF BISMUTH-DOPED LEAD DIOXIDE [J].
CHANG, HP ;
JOHNSON, DC .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :85-94