Gold electrodes from recordable CDs

被引:149
作者
Angnes, L
Richter, EM
Augelli, MA
Kume, GH
机构
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, BR-05508900 Sao Paulo, Brazil
[2] UNESP, Fac Engn Guaratingueta, Guaratingueta, SP, Brazil
关键词
D O I
10.1021/ac000437p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold electrodes are widely used in electrochemistry and electroanalytical chemistry. The notable performance when used in stripping analysis of many ionic species and the extraordinary affinity of thio compounds for its surface make these electrodes very suitable for many applications. This paper reports a simple and novel way to construct gold electrodes (CDtrodes) using recordable CDs as the gold source. The nanometer thickness of the gold layer of recordable disks (50-100 mm) favors the construction of band nanoelectrodes with areas as small as 10(-6) cm(2). The plane surface can be easily used for the construction of conventional-sized gold electrodes for batch or now injection analysis or even to obtain electrodes as large as 100 cm(2). The low price of commercial recordable CDs allows a "one way use". The evaluation and applicability of these electrodes in the form of nanoelectrodes, in batch and associated with flow cells, are illustrated in this paper.
引用
收藏
页码:5503 / 5506
页数:4
相关论文
共 24 条
  • [1] Investigation of the electrode reaction of cytochrome c through mixed self-assembled monolayers of alkanethiols on gold(111) surfaces
    Arnold, S
    Feng, ZQ
    Kakiuchi, T
    Knoll, W
    Niki, K
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 438 (1-2): : 91 - 97
  • [2] Flow-through cell based on an array of gold microelectrodes obtained from modified integrated circuit chips
    Augelli, MA
    Nascimento, VB
    Pedrotti, JJ
    Gutz, IGR
    Angnes, L
    [J]. ANALYST, 1997, 122 (08) : 843 - 847
  • [3] DETERMINATION OF ARSENIC BY ANODIC-STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    FORSBERG, G
    OLAUGHLIN, JW
    MEGARGLE, RG
    KOIRTYOHANN, SR
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (09) : 1586 - 1592
  • [4] Orienting DNA helices on gold using applied electric fields
    Kelley, SO
    Barton, JK
    Jackson, NM
    McPherson, LD
    Potter, AB
    Spain, EM
    Allen, MJ
    Hill, MG
    [J]. LANGMUIR, 1998, 14 (24) : 6781 - 6784
  • [5] SURFACTANT MONOLAYERS ON ELECTRODE SURFACES - SELF-ASSEMBLY OF A VIOLOGEN DERIVATIVE HAVING A CHOLESTERYL HYDROPHOBIC RESIDUE
    LI, J
    KAIFER, AE
    [J]. LANGMUIR, 1993, 9 (02) : 591 - 596
  • [6] Matos RC, 1998, ELECTROANAL, V10, P887, DOI 10.1002/(SICI)1521-4109(199810)10:13<887::AID-ELAN887>3.0.CO
  • [7] 2-Y
  • [8] Flow injection analysis-amperometric determination of ascorbic and uric acids in urine using arrays of gold microelectrodes modified by electrodeposition of palladium
    Matos, RC
    Augelli, MA
    Lago, CL
    Angnes, L
    [J]. ANALYTICA CHIMICA ACTA, 2000, 404 (01) : 151 - 157
  • [9] Amperometric detection with microelectrodes in flow injection analysis: theoretical aspects and application in the determination of nitrite in saliva
    Mori, V
    Bertotti, M
    [J]. TALANTA, 1998, 47 (03) : 651 - 658
  • [10] Glucose oxidase bound to self-assembled monolayers of bis(4-pyridyl) disulfide at a gold electrode: Amperometric determination of glucose
    Murthy, ASN
    Sharma, J
    [J]. ANALYTICA CHIMICA ACTA, 1998, 363 (2-3) : 215 - 220