Quantitative determination of chlorophenols in leather by pressurized liquid extraction and liquid chromatography with diode-array detection

被引:41
作者
Favaro, Gabriella [1 ]
De Leo, Debora [1 ]
Pastore, Paolo [1 ]
Magno, Franco [1 ]
Allardin, Alberto B. [2 ]
机构
[1] Dept Chem Sci, I-35131 Padua, Italy
[2] Tech Inst Leather Tanning Galileo Galilei, I-36071 Arzignano, VI, Italy
关键词
pressurized liquid extraction; leather; chlorophenols; liquid chromatography; spectrophotometric detection;
D O I
10.1016/j.chroma.2007.10.106
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pressurized liquid extraction (PLE) with acetonitrile was used for the recovery of chlorophenols (4-chloro-3-methylphenol, 4-chloro-2-methylphenol, 2,4-dichlorophenol, 2-phenylphenol, 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol and pentachlorophenol) present as biocides in leather. After a single cycle PLE treatment, solutions underwent pre-concentration by evaporation of the solvent under vacuum and clean-up treatment with solid-phase extraction cartridges. Quantitative analysis of the target compounds was carried out by liquid chromatography with gradient elution and UV spectrophotometric detection at variable wavelength for the various analytes in the range 190-240 nm. Instrumental detection limits and operative detection limits in the real matrices were determined according to the Hubaux-Vos approach and to the US Environmental Protection Agency procedures. The detection limits for the seven analytes ranged from 10 to 70 mu g kg(-1). Linearity was very good in the explored range (10(-7)-10(-1) M) giving R-2 values from 0.995 to 1.000 for pentachlorophenol and 2,4-dichlorophenol, respectively. Repeatability was satisfactory, 2-5% for a 1 x 10(-6) M level of concentration, on five repeated measurements on the sample. Recovery yield values with the proposed procedure were determined using spiked samples. Overall recovery ranged from 88 to 97%. The method was used for routine analysis of real leather samples. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 20 条
  • [1] Electroanalytical and chromatographic determination of pentachlorophenol and related molecules in a contaminated soil: a real case example
    Codognoto, L
    Zuin, V
    de Souza, D
    Yariwake, JH
    Machado, SAS
    Avaca, LA
    [J]. MICROCHEMICAL JOURNAL, 2004, 77 (02) : 177 - 184
  • [2] Optimization of a microwave-assisted derivatization-extraction procedure for the determination of chlorophenols in ash samples
    Criado, MR
    da Torre, SP
    Pereiro, IR
    Torrijos, RC
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1024 (1-2) : 155 - 163
  • [3] Development of a solid-phase microextraction method for direct determination of pentachlorophenol in paper and board samples:: Comparison with conventional extraction method
    Domeño, C
    Munizza, G
    Nerín, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1095 (1-2) : 8 - 15
  • [4] Rapid, one-pot derivatization and distillation of chlorophenols from solid samples with their on-line enrichment
    Ganeshjeevan, R.
    Chandrasekar, Raghavan
    Kadigachalam, Parasuraman
    Radhakrishnan, Ganga
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) : 168 - 173
  • [5] Ganeshjeevan R, 2005, J CHROMATOGR A, V1069, P275, DOI 10.1016/j.chroma.2005.01.101
  • [6] DECISION AND DETECTION LIMITS FOR LINEAR CALIBRATION CURVES
    HUBAUX, A
    VOS, G
    [J]. ANALYTICAL CHEMISTRY, 1970, 42 (08) : 849 - &
  • [7] Development of solid-phase extraction and solid-phase microextraction methods for the determination of chlorophenols in cork macerate and wine samples
    Insa, S
    Salvadó, V
    Anticó, E
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (01) : 15 - 20
  • [8] *ISO DIS, 2006, 4044 ISO DIS
  • [9] *IUCTCS, 2003, 144942003 CEN TS IUC
  • [10] Jauregui O, 2001, HANDB ANALYT SEPARAT, V3, P175